F
Nome
XC
XC
XC
Level Description
1008 D
1011 D
1015 D
1Q20
350
350
350
Pr1
Integral time 1
1Q21
0.0
0.0
0.0
Pr1
Band offset 1
1Q22
4.0
4.0
4.0
Pr1
Anti reset wind-up 1
1Q24
0
0
0
Pr1
Minimum capacity of inverter 1
1Q25
255
255
255
Pr1
Maximum time at minimum capacity of
inverter 1
1Q26
2
2
2
Pr1
Time at maximum capacity of inverter 1
2Q1
-
nu
nu
Pr1
Analog output 2 function
2Q2
-
Pbc2
Pbc2
Pr1
Probe for analog output 2
2Q3
-
0.0
0.0
Pr1
Lower limit for analog output 2
2Q4
-
100.0
100.0
Pr1
Upper limit for analog output 2
2Q5
-
50
50
Pr1
Minimum value for analog output 2
2Q6
-
50
50
Pr1
Analog output 2 value after compressor
start
2Q7
-
60
60
Pr1
Analog output 2 value after compressor
off
2Q8
-
50
50
Pr1
Exclusion band start value 2
2Q9
-
50
50
Pr1
Exclusion band end value 2
2Q10
-
50
50
Pr1
Safety value for Analog output 2
2Q11
-
0
0
Pr1
Regulation delay after exit from neutral
zone
2Q12
-
120
120
Pr1
Analog output 2 rise time
2Q13
-
10
10
Pr1
Analog output 2 permanency before load
activation
2Q14
-
2
2
Pr1
Analog output 2 decreasing delay
2Q15
-
5
5
Pr1
Analog output 2 decreasing time
2Q16
-
5
5
Pr1
Analog output 2 permanency before load
off
2Q17
-
5
5
Pr1
Analog output 2 decreasing time after
load off
2Q18
-
4.0
4.0
Pr1
Regulation band width 2
2Q19
-
350
350
Pr1
Integral time 2
2Q20
-
0.0
0.0
Pr1
Band offset 2
2Q21
-
4.0
4.0
Pr1
Anti reset wind-up 2
2Q23
-
0
0
Pr1
Minimum capacity of inverter 2
2Q24
-
255
255
Pr1
Maximum time at minimum capacity of
inverter 2
2Q25
-
2
2
Pr1
Time at maximum capacity of inverter 2
3Q1
4.20mA 4.20mA 4.20mA
Pr1
Analog outputs 3-4 setting
3Q2
nu
nu
nu
Pr1
Analog output 3 function
3Q3
Pbc3
Pbc3
Pbc3
Pr1
Probe for analog output 3
3Q4
0.0
0.0
0.0
Pr1
Lower limit for analog output 3
3Q5
100.0
100.0
100.0
Pr1
Upper limit for analog output 3
3Q6
30
50
50
Pr1
Minimum value for analog output 3
3Q7
40
50
50
Pr1
Analog output 3 value after fan start
XC1015D_V15.doc
Handleiding
Range
0÷999s; with 0 integral action excluded
(-12.0÷12.0°C -12.00 ÷ 12.00BAR, -120÷120°F, -
120÷120PSI; -1200÷1200KPA
0.0÷99.0 °C; 0÷180°F; 0.00÷50,00bar; 0÷725PSI;
0÷5000kPA
0÷99%; with 0 function excluded
1÷255min
1÷255min
FREE – CPR - CPR2 - FAN - FAN2 - INVF1 -
INVF2 - nu
Pbc1(0) - Pbc2(1) ; usata solo quando 2Q2 = 0
-1÷100.00 bar; -15÷750PSI; -50÷150°C; -
58÷302°F;
-1÷100.00 bar; -15÷750PSI; -50÷150°C; -
58÷302°F;
0 ÷ 100 (%)
2Q5 ÷ 100 %
2Q5 ÷ 100 %
2Q6 ÷ 100 %
2Q8 ÷ 100 %
0 ÷ 100 (%)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0.10÷25.00bar; 0.0÷25.0°C; 1÷250 PSI;
1÷250°F;10÷2500 KPA
0÷999s; with 0 integral action excluded
-12.0÷12.0°C -12.00 ÷ 12.00BAR, -120÷120°F, -
120÷120PSI; -1200÷1200KPA
0.0÷99.0 °C; 0÷180°F; 0.00÷50,00bar; 0÷725PSI;
0÷5000kPA
0÷99%; with 0 function excluded
1÷255min
1÷255min
4.20 mA (0) - 0.10 V (1)
FREE – CPR - CPR2 - FAN - FAN2 - INVF1 -
INVF2 - nu
Pbc3(0); Pbc4(1); used with 3Q2 = 0
-1÷100.00 bar; -15÷750PSI; -50÷150°C; -
58÷302°F;
-1÷100.00 bar; -15÷750PSI; -50÷150°C; -
58÷302°F;
0 ÷ 100 (%)
3Q6 ÷ 100 %
rel. 1.5 (11.12.11)
Nome
XC
XC
XC
Level Description
1008 D
1011 D
1015 D
3Q8
40
70
70
Pr1
Analog output 3 value after fan off
3Q9
40
50
50
Pr1
Exclusion band start value 3
3Q10
40
50
50
Pr1
Exclusion band end value 3
3Q11
50
50
50
Pr1
Safety value for Analog output 3
3Q12
0
0
0
Pr1
Regulation delay after exit from neutral
zone
3Q13
150
60
60
Pr1
Analog output 3 rise time
3Q14
10
10
10
Pr1
Analog output 3 permanency before load
activation
3Q15
0
0
0
Pr1
Analog output 3 decreasing delay
3Q16
150
15
15
Pr1
Analog output 3 decreasing time
3Q17
10
5
5
Pr1
Analog output 3 permanency before load
off
3Q18
5
5
5
Pr1
Analog output 3 decreasing time after
load off
3Q19
4.0
4.0
4.0
Pr1
Regulation band width 3
3Q20
500
500
500
Pr1
Integral time 3
3Q21
0.0
0.0
0.0
Pr1
Band offset 3
3Q22
4.0
4.0
4.0
Pr1
Anti reset wind-up 3
3Q24
0
0
0
Pr1
Minimum capacity of inverter 3
3Q25
255
255
255
Pr1
Maximum time at minimum capacity of
inverter 3
3Q26
2
2
2
Pr1
Time at maximum capacity of inverter 3
4Q1
-
nu
nu
Pr1
Analog output 4 function
4Q2
-
Pbc4
Pbc4
Pr1
Probe for analog output 4
4Q3
-
0.0
0.0
Pr1
Lower limit for analog output 4
4Q4
-
100.0
100.0
Pr1
Upper limit for analog output 4
4Q5
-
50
50
Pr1
Minimum value for analog output 4
4Q6
-
50
50
Pr1
Analog output 4 value after fan start
4Q7
-
70
70
Pr1
Analog output 4 value after fan off
4Q8
-
50
50
Pr1
Exclusion band start value 4
4Q9
-
50
50
Pr1
Exclusion band end value 4
4Q10
-
50
50
Pr1
Safety value for Analog output 4
4Q11
-
0
0
Pr1
Regulation delay after neutral zone exit
4Q12
-
60
60
Pr1
Analog output 4 rise time
4Q13
-
10
10
Pr1
Analog output 4 permanency before load
activation
4Q14
-
0
0
Pr1
Analog output 4 decreasing delay
4Q15
-
15
15
Pr1
Analog output 4 decreasing time
4Q16
-
5
5
Pr1
Analog output 4 perm before load off
4Q17
-
5
5
Pr1
Analog output 4 decreasing time after
load off
4Q18
-
4.0
4.0
Pr1
Regulation band width 4
4Q19
-
500
500
Pr1
Integral time 4
4Q20
-
0.0
0.0
Pr1
Band offset 4
4Q21
-
4.0
4.0
Pr1
Anti reset wind-up 4
4Q23
-
0
0
Pr1
Minimum capacity of inverter 4
cod. 1592021021
Range
3Q6 ÷ 100 %
3Q7 ÷ 100 %
3Q9 ÷ 100 %
0 ÷ 100 (%)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0.10÷25.00bar; 0.0÷25.0°C; 1÷250 PSI;
1÷250°F;10÷2500 KPA
0÷999s; with 0 integral action excluded
(-12.0÷12.0°C -12.00 ÷ 12.00BAR, -120÷120°F, -
120÷120PSI; -1200÷1200KPA
0.0÷99.0 °C; 0÷180°F; 0.00÷50,00bar; 0÷725PSI;
0÷5000kPA
0÷99%; with 0 function excluded
1÷255min
1÷255min
FREE – CPR - CPR2 - FAN - FAN2 - INVF1 -
INVF2 - nu
Pbc3(0); Pbc4(1); used with 4Q1 = 0
-1÷100.00 bar; -15÷750PSI; -50÷150°C; -
58÷302°F;
-1÷100.00 bar; -15÷750PSI; -50÷150°C; -
58÷302°F;
0 ÷ 100 (%)
4Q5÷ 100 %
4Q5÷ 100 %
4Q6 ÷ 100 %
4Q8 ÷ 100 %
0 ÷ 100 (%)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0.10÷25.00bar; 0.0÷25.0°C; 1÷250 PSI;
1÷250°F;10÷2500 KPA
0÷999s; with 0 integral action excluded
(-12.0÷12.0°C -12.00 ÷ 12.00BAR, -120÷120°F, -
120÷120PSI; -1200÷1200KPA
0.0÷99.0 °C; 0÷180°F; 0.00÷50,00bar; 0÷725PSI;
0÷5000kPA
0÷99%; with 0 function excluded
Page
28 / 29