Electronische stappenregelaar voor centrales
Inhoudsopgave

Advertenties

F
Nome
XC
XC
XC
Level Description
1008 D
1011 D
1015 D
AI13
-
30.00
30.00
Pr2
Probe 4 readout at 20mA/5V
AI14
-
0.0
0.0
Pr2
Probe 4 calibration
AI15
ALr
ALr
ALr
Pr2
Alarm relay for regulation faulty probe
AI16
ntc
Ntc
Ntc
Pr1
Probe 5 setting (ntc/ptc)
AI17
nu
nu
nu
Pr1
Probe 5 action type
AI18
0,0
0.0
0.0
Pr1
Probe 5 calibration
AI19
ntc
Ntc
Ntc
Pr1
Probe 6 setting (ntc/ptc)
AI20
nu
nu
nu
Pr1
Probe 6 action type
AI21
0,0
0.0
0.0
Pr1
Probe 6 calibration
AI22
ntc
Ntc
Ntc
Pr1
Probe 7 setting (ntc/ptc)
AI23
nu
nu
nu
Pr1
Probe 7 action type
AI24
0,0
0.0
0.0
Pr1
Probe 7 calibration
AI25
ntc
Ntc
Ntc
Pr1
Probe 8 setting (ntc/ptc)
AI26
nu
nu
nu
Pr1
Probe 8 action type
AI27
0,0
0.0
0.0
Pr1
Probe 8 calibration
AI28
ALr
ALr
ALr
Pr1
Alarm relay for AUX faulty probe
DI2
cL
CL
CL
Pr2
LP swtich polarity - circuit 1
DI3
-
CL
CL
Pr2
LP swtich polarity - circuit 2
DI4
cL
CL
CL
Pr2
HP swtich polarity - circuit 1
DI5
-
CL
CL
Pr2
HP swtich polarity - circuit 2
DI6
ALr
ALr
ALr
Pr2
Relay for pressure switch alarm
DI7
cL
CL
CL
Pr2
Safe input polarity compressor circuit 1
DI8
-
CL
CL
Pr2
Safe input polarity compressor circuit 2
DI9
cL
CL
CL
Pr2
Safety input polarity fan circuit 1
DI10
-
CL
CL
Pr2
Safety input polarity fan circuit 2
XC1015D_V15.doc
Handleiding
Range
(AI12 ÷ 100.00)
BAR
(AI12 ÷ 750)
PSI
(dEU=bar o °C)
(dEU=PSI o °F)
-12.0 ÷ 12.0
-120 ÷ 120
nu - ALr - ALr1 - ALr2
ptc(0) - ntc(1)
nu = not used ;
Au1 = Probe for AUX1 thermostat;
Au2 = Probe for AUX2 thermostat;
Au3 = Probe for AUX3 thermostat;
Au4 = Probe for AUX4 thermostat;
otC1 = dynamic set point for delivery – circuit 1
otC2 = dynamic set point for delivery – circuit 2
otA1 = dynamic set point for suction – circuit 1
otA2 = dynamic set point for suction – circuit 2
(dEU=bar o °C)
(dEU=PSI o °F)
-12.0 ÷ 12.0
-120 ÷ 120
ptc(0) - ntc(1)
nu = not used ;
Au1 = Probe for AUX1 thermostat;
Au2 = Probe for AUX2 thermostat;
Au3 = Probe for AUX3 thermostat;
Au4 = Probe for AUX4 thermostat;
otC1 = dynamic set point for delivery – circuit 1
otC2 = dynamic set point for delivery – circuit 2
otA1 = dynamic set point for suction – circuit 1
otA2 = dynamic set point for suction – circuit 2
(dEU=bar o °C)
(dEU=PSI o °F)
-12.0 ÷ 12.0
-120 ÷ 120
ptc(0) - ntc(1)
nu = not used ;
Au1 = Probe for AUX1 thermostat;
Au2 = Probe for AUX2 thermostat;
Au3 = Probe for AUX3 thermostat;
Au4 = Probe for AUX4 thermostat;
otC1 = dynamic set point for delivery – circuit 1
otC2 = dynamic set point for delivery – circuit 2
otA1 = dynamic set point for suction – circuit 1
otA2 = dynamic set point for suction – circuit 2
(dEU=bar o °C)
-12.0 ÷ 12.0
(dEU=PSI o °F)
-120 ÷ 120
ptc(0) - ntc(1)
nu = not used ;
Au1 = Probe for AUX1 thermostat;
Au2 = Probe for AUX2 thermostat;
Au3 = Probe for AUX3 thermostat;
Au4 = Probe for AUX4 thermostat;
otC1 = dynamic set point for delivery – circuit 1
otC2 = dynamic set point for delivery – circuit 2
otA1 = dynamic set point for suction – circuit 1
otA2 = dynamic set point for suction – circuit 2
(dEU=bar o °C)
-12.0 ÷ 12.0
(dEU=PSI o °F)
-120 ÷ 120
nu - ALr - ALr1 - ALr2
OP - CL
OP - CL
OP - CL
OP - CL
nu - ALr - ALr1 - ALr2
OP - CL
OP - CL
OP - CL
OP - CL
rel. 1.5 (11.12.11)
Nome
XC
XC
XC
Level Description
1008 D
1011 D
1015 D
DI11
no
NO
NO
Pr2
Manual restart for compressor alarm
DI12
no
NO
NO
Pr2
Manual restart for fan alarm
DI13
ALr
ALr
ALr
Pr2
Relay for compressor or fan alarm
DI14
CL
CL
CL
Pr1
Polarity of configurable digital input 1
DI15
LL1
LL1
LL1
Pr1
Function of configurable digital input 1
DI16
10
20
20
Pr1
Delay of configurable digital input 1
DI17
CL
CL
CL
Pr1
Polarity of configurable digital input 2
DI18
ES1
ES1
ES1
Pr1
Function of configurable digital input 2
DI19
0
0
0
Pr1
Delay of configurable digital input 2
DI20
CL
CL
CL
Pr1
Polarity of configurable digital input 3
DI21
LL2
LL2
LL2
Pr1
Function of configurable digital input 3
DI22
0
20
20
Pr1
Delay of configurable digital input 3
DI23
CL
CL
CL
Pr1
Polarity of configurable digital input 4
DI24
ES2
ES2
ES2
Pr1
Function of configurable digital input 4
DI25
0
0
0
Pr1
Delay of configurable digital input 4
DI26
ALr
ALr
ALr
Pr1
Relay for LL alarm - circuit 1
DI27
-
ALr
ALr
Pr1
Relay for LL alarm - circuit 2
CP1
4.0
4.0
4.0
Pr1
Regulation band width circuit 1
CP2
-40,0
-40.0
-40.0
Pr1
Minimum set point circuit 1
CP3
10,0
10.0
10.0
Pr1
Maximum set point circuit 1
CP4
0
0.0
0.0
Pr1
Energy saving circuit 1
CP5
-
5.0
5.0
Pr1
Regulation band width circuit 2
CP6
-
-40.0
-40.0
Pr1
Minimum set point circuit 2
CP7
-
10.0
10.0
Pr1
Maximum set point circuit 2
CP8
-
0.0
0.0
Pr1
Energy saving circuit 2
CP9
5
5
5
Pr1
2 start compressor delay
CP10
2
2
2
Pr1
Minimum time load off
CP11
15
15
15
Pr1
2 different load start delay
CP12
5
5
5
Pr1
2 different load off delay
CP13
15
15
15
Pr1
Minimum time load on
CP14
0
nu
nu
Pr1
Maximum time load on (0=nu)
CP15
0
0
0
Pr1
Min time Frq1-2 off after CP14
CP16
no
NO
NO
Pr1
CP11 enabled also at first on
CP17
no
NO
NO
Pr1
CP12 enabled also at first off
CP18
10
10
10
Pr1
Output delay at power on
CP19
-
NO
NO
Pr2
Booster function enabled
F1
4,0
4.0
4.0
Pr1
Regulation band width circuit 1
F2
10,0
10.0
10.0
Pr1
Minimum set point circuit 1
F3
60,0
60.0
60.0
Pr1
Maximum set point circuit 1
F4
0,0
0.0
0.0
Pr1
Energy saving circuit 1
cod. 1592021021
Range
no - YES
no - YES
nu - ALr - ALr1 - ALr2
OP - CL
ES1 - ES2 - OFF1 - OFF2 - LL1 - LL2 -noCRO -
noSTD1- noSTD2
0 ÷ 255 (min)
OP - CL
ES1 - ES2 - OFF1 - OFF2 - LL1 - LL2 -noCRO -
noSTD1- noSTD2
0 ÷ 255 (min)
OP - CL
ES1 - ES2 - OFF1 - OFF2 - LL1 - LL2 -noCRO -
noSTD1- noSTD2
0 ÷ 255 (min)
OP - CL
ES1 - ES2 - OFF1 - OFF2 - LL1 - LL2 -noCRO -
noSTD1- noSTD2
0 ÷ 255 (min)
nu - ALr - ALr1 - ALr2
nu - ALr - ALr1 - ALr2
(BAR)
0.10÷10.00
(°C)
0.0÷25.0
(PSI)
1÷80
1÷50
BAR: (AI2 ÷ SETC1); °C: (-50.0 ÷ SETC1); PSI
: (AI2 ÷ SETC1); °F : (-58.0 ÷ SETC1)
BAR: (SETC1÷AI3); °C : (SETC1 ÷ 150.0); PSI :
(SETC1 ÷ AI3); °F: (SETC1 ÷ 302)
(BAR)
-20.00÷20.00
(°C)
-50.0÷50.0
(PSI)
-300÷300
-90÷90
(BAR)
0.10÷10.00
(°C)
0.0÷25.0
(PSI)
1÷80
1÷50
BAR: (AI5 ÷ SETC2); °C: (-50.0 ÷ SETC2); PSI
: (AI5 ÷ SETC2); °F : (-58.0 ÷ SETC2)
BAR: (SETC2÷AI6); °C : (SETC2 ÷ 150.0); PSI :
(SETC2 ÷ AI6); °F: (SETC2 ÷ 302)
(BAR)
(°C)
(PSI)
-20.00÷20.00
-50.0÷50.0
-300÷300
-90÷90
0 ÷ 255 (min)
0 ÷ 255 (min)
0 ÷ 99.5 (min.1sec)
0 ÷ 99.5 (min.1sec)
0 ÷ 99.5 (min.1sec)
0 ÷ 24 (h) – with 0 the function is disabled
0 ÷ 255 (min)
no - YES
no - YES
0 ÷ 255 (sec)
no - YES
(BAR)
0.10÷10.00
(°C)
0.0÷30.0
(PSI)
1÷80
1÷50.0
BAR: (AI9 ÷SETF1); °C: (-50.0 ÷ SETF1); PSI :
(AI9 ÷ SETF1); °F : (-58.0 ÷ SETF1)
BAR: (SETF1÷AI10); °C : (SETF1 ÷ 150.0); PSI :
(SETF1 ÷ AI10); °F: (SETF1 ÷ 302)
(BAR)
-20.00÷20.00
(°C)
-50.0÷50.0
(PSI)
-300÷300
(°F)
-90÷90
Page
26 / 29
(°F)
(°F)
(°F)
(°F)
(°F)

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Xc1011dXc1015dVgc810

Inhoudsopgave