2/ General alarm reset
If the problem that triggered an alarm above disappears, the buzzer
stops, but the red alarm LED remains on until the next normal cycle.
One of the two keypad keys will stop the buzzer in any cases, but it will only
turn o the red LED if the problem that caused the alarm has been resolved.
The alarms of the remote box also remain active until the problem has been
solved. This prevents the system from being «abandoned» in default.
NOTE : Option of connection to an external alarm (Sanicom®2).
Max. 250 V / 16A
External alarm
Dry contact NO
7. STANDARD
This piece of equipment complies with the EN 12050-2 standard (Lift
station for e uents not containing faecal matter) and European Low
Voltage Directive.
8. INSPECTION AND MAINTENANCE
1/ Inspection
The proper running of the wastewater lifting station must be chec-
ked by user once a month observing at least two starting cycles.
2/ Maintenance
The lifting station has to be regularly maintained by a qualified per-
son. Intervals should:
• Every 3 months for lifting stations installed in commercial premises
• Every 6 months for lifting stations installed in collective buildings
• Once a year for lifting stations installed in individual houses
During maintenance, the following should be done:
a) Check the watertightness of connections by checking pipework to
and from the lifting station
b) Activate the gate valves, check their smooth function and their
watertightness ( grease if necessary)
c) Open and clean up the non return-valve system, check it is func-
tioning correctly
d) Clean up the pumping system and its connections, check the im-
peller and the cutting system (for macerating pumps)
e) Clean up the inside of the collecting tank
f) Visually check the lifting station's electrical control box functions.
Once the checks have been made, restart the lifting station in com-
pliance with the manual instructions to check its proper running.
A report should be issued detailing the checks and any notable
points.
If non-compliances that cannot be solved have been found, the qua-
lified person in charge of the maintenance work has to immediately
inform the lifting station's user.
3/ Maintenance contract
It is advised to the users to establish a maintenance contract for
regular maintenance and checking.
Option of externalising the
alarm signal. Dry contact
(no voltage) NO (normally
open) operated by a relay.
Alarm
contact
can
be
connected to a powered
system. This contact closes
as soon as the station is in
alarm mode (except in the
case of area alarm) and re-
mains closed as long as the
alarm sounds.
11
9. FAULT FINDING GUIDE
DISCONNECT THE STATION BEFORE ANY INTER-
VENTION !
Alarm on Sanicom® 1 device :
FAULT DETECTED
POSSIBLE CAUSES
Flashing red alarm LED
• Water level detection
system faulty
Steady red alarm LED
• Blocked vent pipe
• Blocked discharge
• Blocked pump or out
of order
• Discharge too high or
excessive inflow
LED o
• Power outage
• Faulty printed circuit
board
Alarm on the Sanicom® 2 control box :
FAULT DETECTED
POSSIBLE CAUSES
Siren + flashing red
• Water level detection
general alarm LED
system faulty
Siren + steady red
• Blocked vent pipe
general alarm LED
• The device has
encountered the following
problem: blocked pipe,
pump(s) blocked
• The device has
encountered a power
failure
Siren + general alarm
• Mains cut
LED + flashing yellow
mains LED
10. DISMANTLING
INSTRUCTIONS RESERVED EXCLUSIVELY
FOR QUALIFIED PROFESSIONAL SPECIA-
LISTS
If one of the motors cannot be made to operate cor-
rectly, use of that motor can be "disabled" by setting
the corresponding switch on the board (P1, P2 : Swit-
ches 1 and 2 for motors 1 and 2).
The motor thus "disabled" can be removed. The unit
operates on the other motor.
11. GUARANTEE
2 years guarantee as from its date of purchase subject to correct
installation and correct use.
Any damage due to foreign bodies such as cotton,
condoms, sanitary towels, wet wipes, food, hair, metal,
wood or plastic objects, will not be under guarantee.
Solvents, acids and other chemicals can also cause damage to the
unit, and will invalidate the guarantee.
EN
ACTION TO BE TAKEN
• Consult SFA after-sales
service
• Check that air flows freely
in both directions in the vent
pipe
• Review installation
• Consult the SFA customer
services
• Check the electrical system
• Consult the SFA customer
services
ACTION TO BE TAKEN
• Consult the SFA customer
services
• Check that air flows freely
in both directions in the
vent pipe
• Press the manual start
button to reset the device
(alarm o )
• Consult SFA customer
services
• To stop the siren, press on
the Force Start button
• Check the electrical
system
• Consult the SFA customer
services