EN
DEFINITION OF WARNING SIGNS
Warning indication of a risk for the machine
or its operator.
Warning indication of the presence of a risk
of electrical origin
DISCONNECT THE STATION BEFORE ANY INTER-
VENTION !
1. APPLICATION
Sanicom® is a lifting pump for wasterwater originating from sinks,
clothes washing machines, dishwashers, showers or baths and ba-
sins, used in private or commercial applications (restaurants, hair-
dressings salons,...).
The unit has a high performance level, and is safe and reliable, pro-
vided all the rules for installation and maintenance in this notice are
strictly followed
2. DESCRIPTION
2.1 OPERATING PRINCIPLE
Sanicom® 1 contains 1 pump.
The tank is equipped with 2 tubes, one controls motor activation,
and the second controls the alarm system.
Sanicom® 2 contains two independent pumps. Both pumps operate
alternately to ensure even ware. In case of surcharge operation, both
motors run simultaneously (or if one pump fails, the other takes
over).
The tank is equipped with three dip tubes, two of which control mo-
tor activation, and the third controls the alarm system.
2.2 TECHNICAL DATA
Type
Maximum vertical pumping height
Voltage
Frequency
Maximum power consumption
Maximum current consumption
Electrical class
Protection index
Max. temperature permissible
5 min/h
Net weight
3. INSTALLATION
The Sanicom® installation must comply with EN12056-4 standards.
All work to install the equipment, put it into service and carry out
maintenance must be done by a qualified professional specialist.
3.1 FITTING
• The space in which Sanicom® is installed must be large enough to
leave at least 600mm around the unit for easy maintenance. This
space must be well lit, ventilated, and must never be immersed in
water and must be protected from frost.
• Isolation valves should be fitted to the inlet pipework and discharge
pipework to isolate the unit in case of the need for service.
• This discharge pipe must be designed so as to prevent back-flow
from the sewers. Backflow is avoided by installing an anti-backflow
loop located above the back-flow level.
COMMENT: UNLESS OTHERWISE STATED LOCALLY, THE BACK-
FLOW LEVEL CORRESPONDS TO THE LEVEL OF THE ROAD OR
PAVEMENTS,...
• The pumping station must always be ventilated so that the tank is
always at atmospheric pressure. The ventilation must be completely
free and air must flow in both directions (no diaphragm valve fitted).
Do not connect to a mechanically controlled ventilator.
3.2 ELECTRICAL CONNECTION
Do not make the electrical connection until the final connec-
tions are completed
Sanicom® 1 Sanicom® 2
P 95
R 90
8 m
10 m
220-240 V 220-240 V
50-60 Hz
50-60 Hz
750 W
3 000 W
3.3 A
13 A
I
I
IP X4
IP X4
90°C
90°C
10 kg
26 kg
10
4. COMMISSIONING
Once the plumbing and electrical connections have been made,
check that the connections are watertight by letting water flow suc-
cessively through each inlet used. Make sure that the unit is opera-
ting correctly by carrying out at least two start cycles with water to
test the system.
5. USE
Sanicom® is designed for disposing of greywater originating from
sinks, clothes washing machines, dishwashers, showers or baths and
basins. Sanicom® can pump out hot water.
Do not dispose of concentrated chemical products (acids, solvents,
bases, oxidants, reducers, etc.) into sanitary ware connected to the
Sanicom®.
In the event of power failure, stop all water flow to the appliances
connected to the Sanicom®.
In case of discharge of greasy e uents, the use of a degreasing tank
is essential.
6. CONTROL BOX OPERATION
6.1 SANICOM 1: CONTROL KEYPAD OPERATION
1/ General alarms
Mains alarm:
If the LED is o , there is no power supply.
Level alarm:
If the water level inside the device is abnormally high, the high level
diptube microswitch will activate the motor and the alarm LED lights
up red. If this LED flashes red, it indicates a detection problem for the
normal water level (Long dip tube).
Time alarm:
If the motor runs continuously for more than 1 minute, the red LED
alarm lights up.
2/ Reset alarm
The button on the keypad will only allow you to turn o the red LED
(it will turn green) if the problem that triggered the alarm has been
resolved.
6.2 SANICOM 2 : REMOTE CONTROL BOX OPERATION
1/ General alarms
Yellow LED :
mains supply
Red LED :
alarm
Manual activation :
Motor 1
Manual activation :
Motor 2
Mains alarm:
In case of power failure (or when unplugging the device): the buzzer
is triggered + the red alarm LED lights up + the yellow mains LED
flashes.
Level alarm:
If the water level inside the device is abnormally high: the buzzer is
triggered + the red alarm LED lights up + both motors start-up. If
this LED flashes red, it indicates a detection problem for the normal
water level (Long dip tube).
Time alarm:
If one of the two motors runs for more than 1 minute: the buzzer is
triggered + the red alarm LED lights up + the other motor starts-up.
LED :
- Green : Power on
- Red : Alarm
BUTTON :
Manual motor activation
Alarm reset