5. Replace the rating plate (it is near the gas
supply pipe) with the one for the new type
of gas supply.
You can find this plate in the bag
supplied with the appliance.
If the supply gas pressure is not constant or it
is different from the necessary pressure,
install an applicable pressure adjuster on the
gas supply pipe.
3.13 Adjusting the minimum gas
level on the hob burner
1. Disconnect the appliance from the
electricity.
2. Remove the knob for the hob. If there is
no access to the bypass screw dismount
the control panel before adjustment start.
3. With a thin and flat screwdriver adjust the
bypass screw A.
The model determines the position of the
bypass screw A.
A
A
Changing from natural gas to liquid
gas
1. Fully tighten the bypass screw.
2. Put the knob back.
Changing from liquid gas to natural
gas
1. Unscrew approximately one turn the
bypass screw position A.
2. Put the knob for the hob back.
3. Connect the appliance to the electricity.
WARNING!
Put the mains plug into the mains
socket only if all parts are back into
their initial position. There is a risk of
injury.
4. Light the burner.
40
ENGLISH
Refer to "Hob - Daily use" chapter.
5. Turn the knob for the hob to the minimum
position.
6. Remove the knob for the hob again.
7. Screw on slowly the bypass screw till the
flame becomes minimum and stable.
8. Put the knob for the hob back on.
3.14 Levelling of the appliance
Use small feet on the bottom of appliance to
set the appliance top surface level with other
surfaces.
3.15 Anti-tilt protection
Set the correct height and area for the
appliance before you attach the anti-tilt
protection.
CAUTION!
Make sure you install the anti-tilt
protection at the correct height.
Make sure that the surface behind the
appliance is smooth.
You must install the anti-tilt protection. If you
do not install it, the appliance can tilt.
Your appliance has the symbol shown on the
picture (if applicable) to remind you about the
installation of the anti-tilt protection.