Download Inhoudsopgave Inhoud Print deze pagina

En] Wiring The Garnet Seelevel Ii 709-Rvc Tank Level Sensor To A Gx Device; En] Installation And Configuration - Victron energy Cerbo GX Handleiding

Verberg thumbnails Zie ook voor Cerbo GX:
Inhoudsopgave

Advertenties

VE.Can/N2K or RV-C, unless it's a Venus GX which has two full VE.Can ports. If this limits further use of the GX device too much
in terms of connectivity via VE.Can, it is recommended to use the Garnet SeeLevel 709-N2K instead.
[en] Also note that tank levels displayed on the Victron GX will be in percentage, not actual volume in liters, gallons, or any other
unit of volume.
12.5.1.

[en] Wiring the Garnet SeeLevel II 709-RVC tank level sensor to a GX device

[en] Before connecting to a GX device, ensure that the Garnet SeeLevel 709-RVC has been installed and configured correctly
according to Garnet's installation instructions.
[en] While the VE.Can port requires an RJ45 connector, the Garnet SeeLevel panel features either a multi-pin RV-C connector or
wired connection with one black, one blue and one white wire each. In order to be able to connect both together, an adapter cable
must be built according to the pin assignment in the table below.
[en] A commercially available CAT5 Ethernet cable is best suited for this, whereby one of the two ends is first cut off and then
connected to the Garnet panel.
[en] Garnet panel wire
colour code
[en] Black
[en] Blue
[en] White
12.5.2.

[en] Installation and configuration

1.
[en] Route the cable from the Garnet panel to the GX device.
2.
[en] Make sure both the Garnet and the GX device are powered off.
3.
[en] Connect the RJ45 plug to the VE.Can port of the GX device and the other end of the adapter cable to the Garnet panel.
4.
[en] Make sure the bus termination is correct. For the GX device: Use the included blue
termination is mandatory for the Garnet SeeLevel if it is the only RV-C device.
5.
[en] Once everything is installed correctly, turn on both devices.
6.
[en] Proceed with the RV-C configuration as explained in the
VE.Can port for the RV-C profile.
Pagina 72
Cerbo GX Handleiding
[en] RV-C
[en] Victron
connector
VE.Can RJ45
4
3
3
8
2
7
[en] Victron VE.Can pinout
RV-C Configuration chapter [71]
[en] CAT5 Ethernet wire
colour code
[en] green/white
[en] brown
[en] brown/white
VE.Can RJ45
terminator. Proper bus
to properly configure the
RV-C-ondersteuning
[en] Signal
[en] Ground
[en] CAN-L
[en] CAN-H