4.3.2 - Functional aspects not to be mistaken for anomalies
The following events may occur during normal operation:
a.
The compressor does not start up again immediately after a stop (it takes
about three minutes to start again).
-
In the operating logic of the appliance a delay between a compressor stop
and its successive restart has been included, so that the compressor itself
is protected against activations that are too frequent.
b. During the heating operation of the heat pump appliances, the flow of hot
air may occur some minutes after activation of the compressor.
-
Should the fan start at the same time as the compressor, for the first few
minutes it would emit cold air into the room (and this could bother the occu-
pants) since the unit has not yet reached steady running conditions.
4.3.3 - Console led signals
In the event that the air conditioner is
blocked, the LEDs highlight an alarm
signal as per table "TAB1".
Contact an Olimpia service centre.
H
Reset key.
G
Infrared receiver.
Table "TAB1"
DESCRIPTION
Signalling of the machine in stand-by
Signalling of the machine in operation
Signalling of timer activation, machine on hold
Signalling of timer activation, machine running
Signalling of the ignition of the refrigerator
compressor
Indication of any need to clean the air filter.