After use, turn the gas cylinder tap off.
•
The gas bottle must always be replaced following safety rules away from any
possible source of ignition.
•
The heater must be placed where there is no risk of fire, the hot air outlet
must be at least 3m from any flammable wall or ceiling and must never be
directed towards the gas bottle.
•
If in any doubt contact your supplier.
INSTALLATION
1.
Connect the heater to a suitable electric socket /230V~50Hz
2.
Make sure that the machine is properly earthed.
3.1. Connect the gas supply hose to the pressure regulator and connect the regu-
lator to a suitable LPG cylinder.
3.2. FOR SPAIN, PORTUGAL, DENMARK, FINLAND, NORWAY ONLY: first mount
de 2 bar regulator on the gas bottle. Then connect the 700 mbar regulator to
the 2 bar regulator. Connect 1 side of the gas hose to the 700 mbar regulator
and connect the other side of the gas hose to the heater. See below photo
inst 1, inst 2 and inst 3.
4.
Open the tap of the cylinder and check the supply hose and fittings for gas
leak. For this operation it is recommended to use an approved leak detector.
Inst 1
NOTE: mounting the 2 regulators in series - ONLY FOR SPAIN, PORTUGAL,
DENMARK, FINLAND, NORWAY
INSTRUCTION FOR USE
PREPARING FOR OPERATION
1.
Check the heater for possible shipping damage.
2.
Connect the hose and regulator assembly to the LPG cylinder.
3.
Open the cylinder's gas valve and check all gas connections with a soap and
water solution.
4.
Connect power cord to well-grounded 220V~, 50Hz source of power.
Inst 2
Inst 3
700mbar regulator
0-2bar
regulator
Hose
4
33