Indicators showing the battery's state of health
To check the battery's state of health, press the release button and hold it down for longer than
three seconds. The system does not detect a potential malfunction of the battery due to misuse, for
example battery dropped or pierced, external heat damage, etc.
Status
All LEDs show in sequence, followed by one (1)
LED showing constantly green.
All LEDs show in sequence, followed by one (1)
LED quick-flashing yellow.
All LEDs show in sequence, followed by one (1)
LED showing constantly red.
Parallel guide
Use of the single-arm parallel guide allows precise cuts to be made along the edge of the workpiece,
or strips of even width to be cut.
The parallel guide can be fitted on either side of the base plate.
Technical data
Product properties
Product generation
Rated voltage
Weight
Saw blade diameter
Saw blade disc thickness
Kerf width
Saw blade arbor size
Rated speed under no load
Maximum cutting depth
Maximum material thickness
Storage temperature
Ambient temperature for operation
Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
28
Meaning
The battery can remain in use.
The check to ascertain the battery's state of
health did not complete. Repeat the procedure,
or consult Hilti Service.
If a connected product can still be used, the
remaining battery capacity is below 50 %.
If a connected product can no longer be used,
the battery has reached the end of its useful life
and has to be replaced. Consult Hilti Service.
For mild steel
plates
For stainless steel
plates
SC 6ML-22
01
21.6 V
2.46 kg
(in accordance with
EPTA-Procedure 01 without battery)
160 mm
1.2 mm
1.2 mm
20 mm
4,000 /min
60 mm
8 mm
8 mm
−20 ℃ ... 70 ℃
−17 ℃ ... 60 ℃
21.6 V
See the end of these operating in-
structions
−17 ℃ ... 60 ℃
2360040
*2360040*