7.2.6 Parameter setting
Press
,then press
which parameter will flash.
Code
Name
P0
Mandatory defrosting
P1
Working mode
P2
Timer on/off
P3
Water pump
P4
Current time
P5
Timer on
P6
Timer off
P7
Water temp. calibration
P12
MOBUS COM
P13
MODBUS ID Address
Restore to factory
P14
settings
Parameter P value for
P15
Modbus
P16
Product code
P18
Mode
Note:
1). Long press
for 20s to set P14, P16, P18.
2). P8,P9,P10,P11,P19,P20 parameter is only for factory setting.
7.
7.
7.
Start-up
Start-up
Start-up
of
of
of
the
the
the
to choose P0-P18 value, and press
Scope
Default
0-1
0
0-1
1
0-1
0
0-1
0
HH:MM
00:00
HH:MM
00:00
HH:MM
00:00
-9~9
0
0 - 5
0
1 - 88
9
0-1
0
/
/
/
/
0-1
0
- 95 -
Heat
Heat
Heat
Pump
Pump
Pump
again to enter the setting interface,in
Remark
0: Default normal operation
1: mandatory defrosting.
1:Heating mode, 0:cooling mode,
1 Timer on/off is under function, 0 Timer on/off is out
of function (The setting of P5 and P6 won't work)
1:Always running;
0:Depends on the running of compressor
0-23:0-59
0-23:0-59
0-23:0-59
Default setting: 0
Modbus Only(default value after reset)
Modbus Only(default value after reset)
1-Restore to factory settings,
0- default(restore P0, P1, P2, P3, P5, P6, P7, P8, P9,
10, P11 to factory setting)
Depends on the machine(Modbus Only)
Depends on the machine
1—Heating only,
0—Heating/Cooling/Auto mode