7.2.5 Parameter checking
Press
, then press
Code
d0
IPM mould temperature
d1
Inlet water temp.
d2
Outlet water temp.
d3
Ambient temp.
d4
Frequency limitation code
d5
Piping temp.
d6
Gas exhaust temprature
d7
Step of EEV
d8
Compressor running frequency
d9
Compressor current
d10
Current fan speed
d11
Error code for last time
d12
MOBUS COM
d13
MODBUS ID Address
d14
Product Code
Remark:
d4: Frequency limitation code,
0: No frequency limit;
2: Overheating or overcooling frequency limit; 4:Drive Current frequency limit;
8:Drive voltage frequency limit;
7.
7.
7.
Start-up
Start-up
Start-up
of
of
of
to check d0-d14 value.
Condition
1:Coil pipe temperature limit;
16:Drive high temperature frequency limit
the
the
the
Heat
Heat
Heat
Pump
Pump
Pump
Scope
0-120℃
-9℃~99℃
-9℃~99℃
-30℃~70℃
0,1,2,4,8,16
-30℃~70℃
0℃~C5℃ (125℃)
0~99
0~99Hz
0~30A
0-1200 (rpm)
All error code
0 - 5
1 - 88
0000- FFFF
- 94 -
Remark
Real testing value
Real testing value
Real testing value
flash if Real value<-9
Real testing value
flash if Real value<-9
Real testing value
N*5
Real testing value
Real testing value
Real testing value
Setting, Modbus Only
Setting, Modbus Only
Setting, Modbus Only