ATTENTION:
Please observe the following rules when installing the heat pump:
1.
Any addition of chemicals must take place in the piping located downstream from the heat pump.
2.
Always keep the heat pump upright. If the unit has been held at an angle, wait at least 24 hours
before applying mains power to the heat pump.
5.1 Heat pump location
The unit will work properly in any desired location as long as the following three items are present:
The unit may be installed in virtually any outdoor location as long as the specified minimum distances to other
objects are maintained (see drawing below). Please consult your installer for installation with an indoor pool.
Installation in a windy location does not present any problem at all.
ATTENTION:
1. Never install the unit in a closed room with a limited air volume in which the air expelled from the unit
will be reused, or close to shrubbery that could block the air inlet. Such locations impair the continuous
supply of fresh air, resulting in reduced efficiency and possibly preventing sufficient heat output.
2. When the appliance is installed and protected by a residual current device (RCD) with a maximum
amperage of 30mA, it should be installed at a distance of at least 2 meters from the edge of the pool. If no
RCD is installed with the appliance, it should be installed at a distance of at least 3.5 meters from the edge
of the pool.
5.
5.
5.
Location
Location
Location
and
and
and
1. Fresh air
2. Electricity
3. Swimming pool filters
- 81 -
connection
connection
connection