The connections must be dimensioned according to the power of the device and the state of installation.
Models
PET-08
PET-10
PET-13
PET-15
PET-19
PET-25
PET-30
PET-30T
PET-35
PET-35T
These values are given as a guideline, only an authorized electrician can determine the values
corresponding to your installation.
The electric cable must be equipped with a ground connection and with a circuit breaker with
differential 30mA.
6.6 Installation of the display deportee (option)
Photo(1)
- The end with plug connects with the control panel (photo1)
- The other end of the signal wire. (photo2)
- Open the cover of the terminal box and pass through it the cable of the remote screen.(photo3,4)
- Insert the wiring into the designated position on the Modbus Module. (photo5)
6.
6.
6.
Electrical
Electrical
Electrical
Circuit breaker
7 A
9 A
11A
14 A
16 A
20 A
26 A
10.5 A
34 A
13 A
Photo(2)
Photo(3)
Wiring
Wiring
Wiring
Maximum length of the wire
2,5 mm²
4 mm²
84 m
135 m
57 m
90 m
43 m
68 m
34 m
54 m
29 m
45 m
25 m
/
15 m
35 m
/
/
12 m
27 m
Photo(4)
- 90 -
6 mm²
10 mm²
200 m
335 m
130 m
225 m
100 m
170 m
80 m
135 m
66 m
110 m
38 m
62 m
49 m
81 m
22 m
36 m
39 m
68 m
Photo(5)