INSTaLLaTION
Installation
10.2.3 Oversink installation, non-pressurised, with non-
pressurised tap
Tap installation
Material losses
!
f When making the connections, counter the torque
on the appliance using a size 14 spanner.
f Install the tap. For this, also observe the tap operating and
installation instructions.
www.stiebel-eltron.com
Appliance installation
f Fit the appliance to the tap with the water connections.

10.3 Making the electrical connection

DANGER Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
DANGER Electrocution
Ensure that the appliance is earthed.
Ensure the appliance can be separated from the power
supply by an isolator that disconnects all poles with at
least 3 mm contact separation.
DANGER Electrocution
The appliances are delivered with a power cable
(EIL 3 Trend with plug).
Connection to a permanent power supply is possible,
provided the fixed cable has a cross-section that is at
least equal to that of the standard power cable of the
appliance. A maximum cross-section of 3 x 6 mm² may
be used.
f If the appliance is installed over the sink, route the
power cable behind the appliance.