Download Print deze pagina

Auerswald COMmander 6000 Gebruikshandleiding pagina 56

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 212
Commissioning (COMmander 6000)
Mounting the mounting frame on the wall
1.
Hold the mounting frame vertically on the area where the device
is to be mounted and place marks where the mounting holes are
to be drilled into the wall.
Important: A minimum of 150 mm clearance must remain above
the casing in order to remove and install the cover.
2.
Drill the mounting holes (6 mm) and insert dowels into the holes.
3.
Fasten the mounting frame on the wall using the screws.
Reinstalling the mounting rack
Note: To prevent the cable in the USB casing socket from
becoming pinched, roll up the cable and place it near the socket in
the cable space.
1.
Hold the mounting rack diagonally with the upper edge towards
the wall and install it at the top in the mounting frame.
2.
In addition, press the lower part of the mounting rack onto the
mounting frame until the lock snaps in.
Connecting the Earthing
Warning: Touching voltage-carrying conductors or phone connections can cause
life-threatening electric shocks. The PBX contains hazardous voltages, even outside
of the power supply unit (for instance ringer voltages). Work on active, contact-
hazardous parts is only permitted after creating a voltage-free state. Working close to
active parts is only permitted if these parts are voltage-free or are protected against direct
contact.
• Disconnect terminal devices from the PBX. No terminal devices should be connected
during the installation of the earthing. Connected terminals may feed-in currents which
might cause electrical shocks.
• Pull out the PBX's power plug. Also disconnect the device from additional power sources
(e. g. UPS) if installed.
• Wait at least 3 minutes for the discharge of any capacitor in the device after
disconnecting it from the main power supply.
• Only a fixed installation is allowed for the connection of the earthing terminal of the PBX
to the potential compensation bar of the house installation or the protective earth
conductor. Plug connections are not allowed.
Requirements:
• Screw driver
• Connecting cable with at least 2.5 mm
56
²
conductor cross-section
COMmander 6000/R/RX - Instructions V11 11/2018

Advertenties

loading

Deze handleiding is ook geschikt voor:

Commander 6000rxCommander 6000r