Inserting a Module
1.
Guide the module between the two
circuit board latches.
2.
Press it vertically downwards to the
base circuit board until it snaps in
securely.
Removing a Module
1.
Push the circuit board latch on the
slanted side of the module a short
distance away from the module.
2.
Using the other hand, simultaneously
remove the module almost vertically
from the base circuit board.
Note: If you have VMF and VoIP modules, these
have to be connected to the basic unit or to the
adjacent VMF/VoIP module. The free RJ-45 socket
of the last VMF/VoIP module is for connecting to the
network.
Wall-Mounting the PBX
Warning: Touching voltage-carrying conductors or phone connections can cause
life-threatening electric shocks. The PBX contains hazardous voltages, even outside
the power supply unit (for instance ringer voltages). Work on active, contact-
hazardous parts is only permitted after creating a voltage-free state. Working close to
active parts is only permitted if these parts are voltage-free or are protected against direct
contact.
• Mount the PBX close of an earth wire (potential compensation bar of the house
installation or protective earth conductor). Connect the PBX's earth connection to the
earth wire with a connecting cable whose conductor diameter is at least 2.5 mm
• Pull out the power plug of the PBX. If necessary, also disconnect the devices from
additional power sources (e. g. UPS).
• Wait at least 3 minutes for the discharge of any capacitor in the device after
disconnecting it from the main power supply.
54