Internal Analogue Port for Analogue Terminals
Loop current
Feeder
Range
Call voltage
Audible signals
Charge pulse
Impedances
Internal S0 Port for ISDN Terminals
Connection type
Supply voltage
Feeder
Range
Terminators
Internal UP0 Port for ISDN Terminals
Connection types
Range
Supply voltage
Feeder
External S0 Port for ISDN Network Provider
Connection type
48
Approx. 23 mA
0.5 W
2 x 50 ohm, approx. 800 m at 0.6 mm diameter
Approx. 45 V
, configurable: 25/50 Hz
eff
425 Hz +/-5 %, interval +/-10 %
Configurable: 12/16 kHz
Symmetrical
S
basis access as Point-to-Multipoint connection, EURO-
0
ISDN (DSS1), short passive bus
40 V +5 % / -15 %
Max. 4 W
Max. 150 m with typical phone or network cable (twisted-
pair) for bus setup; European standards ENV 41001
[DINV 41001] and EN 28877 apply to IAE-termination
technology)
Max. 1000 m for PTP wiring
100 ohm, switchable; factory settings on
U
with Euro-ISDN protocol (DSS1); 2 B-channels per
P0
port, direct connection to a U
adapter
At 0.6 mm diameter:
Screened cable: up to 600 m
Unscreened cable: up to 1000 m
40 V +5 % / -15 %
Max. 4 W
S
basis access as Point-to-Multipoint connection or as a
0
Point-to-Point connection, EURO-ISDN (DSS1), unit is
powered locally