Freezer compartment door
was open for a long time;
temperature is no longer
reached.
Appliance is not cooling,
temperature display and light
are lit.
Automatic super freezing
does not switch on.
The evaporator (refrigeration
generator) in the NoFrost
system is covered in thick ice
and can no
longer be defrosted fully
automatically.
Showroom mode is
switched on.
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance. Fig. *
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.
Start appliance self-test (see chapter
"Appliance self-test").
When the programme has ended,
the appliance switches over to normal
operation.
The appliance decides independently whether
automatic Super freezing is required and
automatically switches it on or off.
en