2.11 Special accessories
• Surface mounting set
Order no. : 07 14 31
3. Fault elimination
Fault
• Unit fails to heat up
• Unit switches off before reaching boiling point
• Hot water outflow (4) is clearly reduced
despite fully opened tap (3)
Table 3
If the problem is associated with the electrical supply consult a qualified person.
4. Fault elimination
Fault
• Unit fails to heat up
• Indicator lamp fails to light up despite unit
being switched on
• Water intake (4) clearly reduced despite
fully opened tap (3)
• Tap fitting leaking
Table 4
5. Environment and
recycling
Recycling of obsolete appliances
Appliances with this label must not
be disposed off with the general
waste. They must be collected
separately and disposed off according to local
regulations.
12
• Swivel arms for fitting outlet pipe
Order no.: see sales information of
Stiebel Eltron
by the user
Cause
– No electricity supply
– Unit not switched on
– Fuse defective
– No water in the unit
– Unit affected by scaling
– Scaling / dirt
by the qualified installer
Cause
– Disc-type heating element / thermostatic
limiter defective
– Indicator lamp defective
– Isolating valve is blocked
– 'O' ring defective
6. Guarantee
For guarantees please refer to the pespective
terms and conditions of supply for your
country.
The installation, electrical connection
and first operation of this appliance
should be carried out by a qualified installer.
The company does not accept liability for
failure of any goods supplied which accor-
dance with the manufacturer's instructions.
• Tundish
Order no.: 00 68 88
Remedy
– Check electricity supply is available
– Switch unit on
– Check fuses in the house wiring
installation: user / qualified installer
– Add water (1)
– Descale the unit
– Descale the unit
Remedy
– Check and if necessary replace disc-type
heating element (29) / thermostatic
limiter (26)
– Replace indicator lamp
– Clean the isolating valve
– Check 'O' ring if necessary replace 'O'
ring