INSTALLATION
Installation
8.3
Transportation to the installation site
Material losses
!
We recommend removing the cylinder casing for trans-
portation to the installation site to prevent it from be-
coming dirty or damaged (see chapter "Removing the
cylinder casing").

8.3.1 Removing the cylinder casing

1 Cover
2 Cylinder casing
3 Plinth trim
f First remove the cover and then the plinth trim.
f
f Remove the cylinder casing.
f
SBP 700 E | SBP 700 E SOL
The appliance has side insulation sections that can be removed.
This will facilitate transportation through narrow doors and pas-
sageways.
f Remove the retaining straps by opening the closures.
f
When reattaching the retaining straps, ensure that the closures
are by a joint between the casing sections.
16
| SBP 200-700 E | SBP 700 E SOL
8.4

Positioning the appliance

SBP 200-400
This appliance comes with adjustable feet as standard.
f The adjustable feet can be extended outwards to compensate
f
for any unevenness in the floor.
SBP 700
This appliance does not have adjustable feet. The floor must be
level.
1
8.5

Installation versions

Installing the threaded immersion heater
2
The threaded immersion heater is used for electric booster heat-
ing.
- With the SBP 200-400, the threaded immersion heater can be
mounted on the right hand or left hand side.
3
- One or two threaded immersion heaters can be mounted
with the SBP 700.
f Remove the cap from the connection.
f
f Undo the plug with a socket spanner size 32.
f
SBP E