INSTALLATION
Safety
1.3
Units of measurement
Note
All measurements are given in mm unless stated oth-
erwise.
2.
Safety
2.1
Intended use
The appliance is designed to store and heat heating water.
The appliance is intended for the seasonal storage (around
5 months at a room temperature of 24 °C and relative humidity of
40 %) of heating water cooled to +7 °C. Constant cooling operation
with heating water below +11 °C is not permissible.
Any other or additional use is regarded as inappropriate, in par-
ticular any usage with alternative storage media. Observation of
these instructions and of the instructions for any accessories used
is also part of the correct use of this appliance.
3.
Appliance description
This appliance is designed to extend the operating time of the
heat generator and to bridge power-OFF periods. It also enables
hydraulic separation of the liquid flowing in the heat generating
circuit and the heating circuit.
A threaded immersion heater can be installed to boost the tem-
perature of the heating water.
The appliance is equipped with complete thermal insulation to
protect against the formation of condensate.
SBP 700 E SOL
The appliance is additionally equipped with a smooth tube indirect
coil for solar booster heating of the heating water.
4.
Cleaning, care and maintenance
f Never use abrasive or corrosive cleaning agents. A damp
f
cloth is sufficient for cleaning the appliance.
5.
Troubleshooting
Call your qualified contractor. To facilitate and speed up your en-
quiry, please provide the serial number from the type plate (no.
000000-0000-000000):
14
| SBP 200-700 E | SBP 700 E SOL
INSTALLATION
6.
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
6.2
7.
7.1
The following are delivered with the appliance:
- 3 sensor well cover sleeves and plugs
- 1 plug
7.2
- Threaded immersion heater
- Compact installations
8.
8.1
Install the appliance near the heat generator in a room free from
the risk of frost.
Ensure the floor has a sufficient load bearing capacity (see chapter
"Specification / Data table").
Observe the room height (see chapter "Specification / Data table").
Nr. 000000-0000-000000
Safety
General safety instructions
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.