Note:
¡ Briefly press
to move the appliance down into the
last saved position.
¡ Press and hold
for approx. 3 seconds to move
the appliance down as far as it will go.
Moving the appliance up
Press .
▶
a The appliance moves up.
Note:
¡ Briefly press
to move the appliance up into the
last saved position.
¡ Press and hold
for approx. 3 seconds to move
the appliance up as far as it will go.
7.4 Selecting a fan setting
Press
or
.
▶
a The LED for the set fan setting lights up in the LED
display.
7.5 Switching on intensive mode
If particularly strong odours or vapours develop, you
can use intensive mode.
Note: Intensive mode 1 can be set in the Home Con-
nect app.
Press
repeatedly until LED 5 lights up in the LED
▶
display for intensive mode 2.
a After approx. 6 minutes, the appliance automatically
switches to fan setting 3.
7.6 Switching off intensive mode
To select a fan setting of your choice, press
▶
7.7 Switching on the fan run-on
During the fan run-on, the appliance continues to run
for a short time and then switches off automatically.
The fan run-on removes remaining odours and is used
to dry the odour filter after the cooking process.
a LED 1 for the fan setting lights up in the LED dis-
play. LED 6 flashes for the fan run-on.
a The appliance switches off automatically after ap-
prox. 10 minutes.
7.8 Switching off the fan run-on
Press
.
▶
a This temporarily stops the fan run-on.
7.9 Switching on intermittent ventilation
With interval ventilation, the ventilation switches on for
approx. 6 minutes every hour.
Note: In the Home Connect app, you can set the time
and fan setting individually.
Press
.
▶
a In the LED display, LED 6 flashes continuously, the
LED for the selected fan setting lights up on the ap-
pliance.
1
Depending on the appliance specifications
a As soon as the ventilation time ends, the LED for
the fan setting you have selected goes out. LED 6
continues to flash.
7.10 Switching off interval ventilation
Press
▶
7.11 Switch on automatic mode
The optimum fan setting is set automatically using a
sensor.
Press .
▶
a In the LED display, LED 6 lights up for automatic
mode.
7.12 Switching off automatic mode
Press .
▶
a The appliance switches to the fan setting that was
previously set.
a The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a Automatic mode runs for a maximum of four hours.
Note: If automatic mode is ended using the
the appliance moves to the run-on position. After ap-
prox. 10 minutes, the appliance switches off automatic-
ally and moves up as far as it will go.
7.13 Sensor control
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
.
timum fan setting is automatically switched on.
If the sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡ Default setting: Fan setting 3
¡ Lowest setting: Fan setting 1
¡ Highest setting: Fan setting 5
7.14 Setting the sensor control
Requirement: The appliance is switched off.
Press and hold
1.
Press
2.
To cancel the setting, press .
To save the setting, press and hold
3.
prox. three seconds.
Or wait approx. 10 seconds until the setting is
saved automatically.
a A signal tone sounds as soon as the selected set-
ting is saved.
7.15 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement: The appliance is switched off.
Press and hold
1.
.
1
and for approx. three seconds.
or
to change the setting.
and
for approx. three seconds.
Basic operation en
1
1
button,
and for ap-
29