INSTaLLaTION
maintenance
Activating the safety pressure limiter
1
2
1 1-pole safety pressure limiter EIL 4 Plus / EIL 6 Plus
2 2-pole safety pressure limiter EIL 3 Plus / EIL 7 Plus
www.stiebel-eltron.com
14. Maintenance
DANGER Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
14.1 Draining the appliance
DANGER Scalding
Hot water may escape during draining.
If the appliance needs to be drained for maintenance or to protect
the whole installation when there is a risk of frost, proceed as
follows:
f Close the shut-off valve in the cold water inlet line.
f Open the draw-off valve.
f Undo the water connections on the appliance.
EIL Plus |
15