Download Print deze pagina

Stiebel Eltron EIL 3 Plus Handleiding Voor Bediening En Installatie pagina 13

Hydraulisch gestuurde mini

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 46
INSTaLLaTION
Commissioning
10.3 Making the electrical connection
DANGER Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
DANGER Electrocution
Ensure that the appliance is earthed.
Ensure the appliance can be separated from the power
supply by an isolator that disconnects all poles with at
least 3 mm contact separation.
DANGER Electrocution
The appliances are delivered with a power cable
(EIL 3 Plus with plug).
Connection to a permanent power supply is possible,
provided the fixed cable has a cross-section that is at
least equal to that of the standard power cable of the
appliance. A maximum cross-section of 3 x 6 mm² may
be used.
Material losses
!
When making the connection to a standard safety socket
(in the case of a power cable with plug), ensure that the
socket is freely accessible after the appliance has been
installed.
www.stiebel-eltron.com
Material losses
!
Observe the type plate. The specified voltage must match
the mains voltage.
f Connect the power cable as shown in the wiring diagram
(see chapter "Specification / Wiring diagram").
11. Commissioning
11.1 Initial start-up
f Fill the appliance by running the tap several times until the
pipework and appliance are free of air.
f Carry out a tightness check.
f Insert the power cable plug, if present, into the standard
safety socket or set the fuse/MCB.
f Check the appliance function.
EIL Plus |
13

Advertenties

loading

Deze handleiding is ook geschikt voor:

Eil 4 plusEil 6 plusEil 7 plus