Download Inhoudsopgave Inhoud Print deze pagina

Fault Rectification - Qualified Installer - Stiebel Eltron SHZ 30 LCD electronic comfort Gebruiks- En Montagehandleiding

Gesloten tweespan-wand
Verberg thumbnails Zie ook voor SHZ 30 LCD electronic comfort:
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 32
7. Fault rectification
Code enquiry
LCD display
Button Note
Fault / defect code / Info
No display in the control panel.
Ca-scale symbol shows
Service symbol.
Code
Continuous display -
setpoint temperature.
Code
Code
No anode protection.
Code
Last preset setpoint values
active. Possibly continuous
display of
Defect symbol >> flashing.
Code
Continuous display -
setpoint temperature.
Code
No heating-up symbol.
Code
Running dry protection.
Code
22
22
22
by the qualified installer
Menu selection.
Code enquiry for service.
Possible cause / defect
No voltage.
No connection to the control unit.
Control unit defective.
Heating element scaled. Heating continues.
Water heating continues.
Maintenance requirement.
Temperature sensor fault.
Parasitic current anode fault.
Communication fault with electronic
„regulator" and „control unit" modules.
.
No water heating.
Temperature sensor defective.
Safety thermal cut-out (STB) actuated.
Heating element defective.
No water in the reservoir.
No anode current.
Relay defective.
Rectification
Restore voltage supply.
Check that connector „X2" is correctly
H
fitted
.
Check control unit (21) and if necessary
replace.
Descale element. Symbol will disappear.
Service code enquiry.
Service / maintenance required.
Check that connector „X10" is correctly
L
fitted
. Inspect temperature sensor.
Check that connector „X7" is correctly
L
fitted
. Check parasitic current anode and
wiring.
Check that connector „X2" is correctly
H
fitted on both modules
.
Check connection cable and modules.
Defect code enquiry.
Corrective maintenance urgently
required!
Check that connector „X10" is correctly
L
fitted
. Inspect temperature sensor.
Eliminate error and reset thermal cut out.
Rectify cause and unlock; inspect STB and if
necessary replace.
Fill the reservoir with water.
Check that connector „X7" is correctly
L
fitted
. Inspect parasitic current anode
and wiring.
Replace regulator electronic module ( 23 ).

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Shz 50 lcd electronic comfortShz 80 lcd electronic comfortShz 100 lcd electronic comfortShz 120 lcd electronic comfortShz 150 lcd electronic comfortShz 30 lcd ... Toon alles

Inhoudsopgave