40 progress
Replacing the lamp
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to
"Installation".
INSTALLATION
Read the "Safety Information" carefully
for your safety and correct operation of
the appliance before installing the
appliance.
Positioning
Install this appliance at a location where the
ambient temperature corresponds to the
climate class indicated on the rating plate of
the appliance:
Climate
Ambient temperature
class
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Electrical connection
Before plugging in, ensure that the voltage
and frequency shown on the rating plate
correspond to your domestic power supply.
All manuals and user guides at all-guides.com
1. Disconnect the mains plug from the
mains socket.
2. Remove the screw from the lamp cov-
er.
3. Remove the lamp cover (refer to the il-
lustration).
4. Replace the used lamp with a new
lamp of the same power and specifical-
ly designed for household appliances.
(the maximum power is shown on the
lamp cover).
5. Install the lamp cover.
6. Tighten the screw to the lamp cover.
7. Connect the mains plug to the mains
socket.
8. Open the door. Make sure that the
lamp comes on.
3. If necessary, replace the defective door
gaskets. Contact the Service Center.
The appliance must be earthed. The power
supply cable plug is provided with a contact
for this purpose. If the domestic power sup-
ply socket is not earthed, connect the appli-
ance to a separate earth in compliance with
current regulations, consulting a qualified
electrician.
The manufacturer declines all responsibility
if the above safety precautions are not ob-
served.
This appliance complies with the E.E.C. Di-
rectives.
Door reversibility