Err 1.3 Battery temperature (was) too high when
discharging
The temperature inside the battery has become too
high during cycling. This can happen under conditions
of extreme heat and great exertion. Ride without
pedal assistance or don't use the bike until the battery
has cooled off. As soon as the battery has cooled off,
you can use it again. (Photo 33)
Err 1.4
Error in communicating with the
battery
Remove the battery and place it back. If this doesn't
help, you must go to your dealer. He will then check
the bike and battery for you and fix the malfunction.
(Photo 34)
Err 2.1 Error in the file system
An error has occurred in the bike control unit. This
message should disappear automatically. You can
continue to bike. If this message recurs, we advise you
to go to your dealer so that he can fix the malfunction.
(Photo 35)
Err 2.2 Temperature in the bike control unit too high
The temperature in the bike control unit (which is
located in the headlight) has become too high. This
malfunction can occur upon very long lasting and
extensive use. If this message appears during cycling, we
advise you to ride without pedal assistance for a while,
until the bike control unit has cooled off. This message
should disappear automatically. (Photo 36)