Technische handleiding interface – MOVITRAC
Naam
Bereik / fabrieksinstelling
Display MOVITOOLS
Vertragingstijd
0 ... 1 ... 10 [s]
1 / 2
Klembezetting
Binaire ingangen
Bezetting binaire
ingang DI02
Bezetting binaire
ingang DI03
Bezetting binaire
ingang DI04
Bezetting binaire
ingang DI05
Bezetting binaire
ingang DI00
Binaire uitgangen
Bezetting binaire
uitgang DO01
Bezetting binaire
uitgang DO02
Bezetting binaire
uitgang DO03
Analoge uitgangen AO1 (optie)
AO1 analoge
0
uitgang
1
2
3
4
5
6
7
11
12
AO1-referentie
0
1
2
AO1 bedrijfssoort
0
2
3
4
AO1 karakteris-
–100 % ... 0 ... +100 %
tiek x1
AO1 karakteris-
0 ... 100 %
tiek y1
®
B
Inbedrijfstelling
Parameterlijst
®
MotionStudio
0: No function
1: Enable / Stop (factory setting DI03)
2: CW / Stop
3: CCW / Stop (factory setting DI02)
4: n11 / n21 (factory setting DI04)
5: n12 / n22 (factory setting DI05)
n13 = n11 + n12
6: Fixed setpoint switchover
7: Parameter set switchover
9: Motor potentiometer up
10: Motor potentiometer down
11: /External fault
12: Fault reset (factory setting DI00)
20: Setpoint acceptance active
26: TF message (only with DI05)
30: Controller inhibit
0: No function
1: /Fault (factory setting DO01)
2: Ready for operation (factory setting DO03)
3: Output stage on
4: Rotating field on
5: Brake released (factory setting DO02 /
not with DO03)
7: Parameter set
9: Speed reference message
11: Comparison message setpoint –
actual value
21: IPOS output
22: /IPOS fault
23: PI controller actual value reference
24: Ex-e current limit active (in preparation)
No function
Ramp generator input
Setpoint speed
Actual speed
Actual frequency
Output current
Active current
Unit utilization
Actual speed (signed)
Actual frequency (signed)
3000 rpm, 100 Hz, 150%
n
max
n
setp-ref
No function
0 ... 20 mA
4 ... 20 mA
0 ... 10 V
I
4
0 0
Waarde na
inbedrijf-
stelling
19