7 .6

Internal fuse

There is an internal fuse on the controller in the connection box.
This fuse protects the controller and the motor against short circuits
or overload.
Always replace a defect fuse by a fuse of the same value .
7 .7

Configuration of one or more motors

By default, the E-Line motor is configured for use in a single-motor
propulsion system. Only if multiple motors are installed one of the
E-Line motors must be configured.
Only work on the system when the motor is stopped and the
electrical system is switched off .
• Remove the cover and flip the switch. It is located on the under-
side of the circuit board (PCB). If necessary, temporarily loosen the
bolts and nuts on the PCB holder.
• Move the switch from position 1 to position 2. The E-Line motor is
now configured for use in a multi-motor system.
• Replace the cover.
The direction of rotation of the motor can be set on the
control panel .
26
370301.01
n
ote
D
anGer
n
ote
PCB
7 .8

The motor control panel

1
The image shown is for illustrative purposes and may differ from the
indicated product. For the exact data, consult the manual of the re-
spective control panel.
Start/Stop control button (1)
With this button the system can be switched on and off. In addition,
this button can be used to take over the command if multiple steer-
ing positions are used.
Power mode (if available) (2)
Pressing the POWER modus button unleashes the electric peak pow-
er of the E-Line motor. Press the button again to return to the NOR-
MAL mode.
The POWER mode will automatically switch off after a few minutes,
after which the mode will be temporarily unavailable.
Eco mode (if available) (3)
By pressing the ECO modus button the maximum output power of
the E-Line motor is limited. Press the button again to return to the
NORMAL mode.
7 .9

Connecting CAN bus (control current) cables

See diagrams from page
36
ed.
The CAN bus power supply must always be
n
connected to 12 Volt . Use the V-CAN key
ote
switch (e .g . MPE1KB) as power supply .