Download Inhoudsopgave Inhoud Print deze pagina

Main Current Cables - Vetus ELINE050 Bedieningshandleiding

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

- Never fit switches or other electrical equipment in the vicinity of
batteries; possible sparks could cause an explosion.
- Prevent metal objects from accidentally coming into contact with
a battery terminal.
7 .5

Main current cables

• Connect the motor to the batteries as shown in the diagrams, see
page 34.
• Fit the fuse supplied and a main switch in the positive (+) cable.
When calculating the cable cross-sections, take into account a
maximum permissible voltage drop of 5% .
Never use smaller cable cross-sections than indicated in the
table below .
Motor type
E-Line 50
Battery cable
50 mm
2
Fuse
250 A
When the batteries are not being used or not charged, it is recom-
mended that they are disconnected from each other using an isolat-
ing switch.
n
fit the fuse, main switch or isolating switches in the
ever
battery space!
Take the following points into account when installing the battery
cables:
- Fit the cables in the shortest possible way from batteries to motor.
- With a long cable length, bundle the '+' and '-' cables together.
- Install the '+' and '-' preferably in such a way that the total length of
each cable is the same. This ensures an equal load on each battery.
- Ensure that the cables do not run through any bilge water.
- Ensure that the cables cannot come into contact with any sharp
edges.
Power consumption indication displacement vessel
Waterline length
4 m (13 ft)
6 km/u (3.3 kn)
Gentle sailing
1 kW
7.2 km/u (3.8 kn)
Cruising speed
1.5 kW
9 km/u (4.9 kn)
Hull speed
3.1 kW
vetus® Installation instructions and operation manual E-Line electric propulsion
W
arninG
E-Line 75
E-Line 100
70 mm
2
95 mm
2
300 A
355 A
W
arninG
6 m (19 ft)
6 km/u (3.3 kn)
0.7 kW
8.8 km/u (4.7 kn)
2.1 kW
11 km/u (5.9 kn)
4.1 kW
- Fix the cables in such a way to prevent wear or abrasion caused
by vibration.
- Use cable terminals to connect the cables to switches, fuse and
motor.
- Preferably fit cable terminals by crimping.
- Use good quality battery terminals to connect the cables to the
battery posts.
- Tighten bolts securely to ensure a good connection.
- Do not use spring-loaded battery terminals!
- Grease the battery posts and battery terminals with Vaseline to
prevent corrosion.
- Never change over the connector cables.
- Before leaving, check the charge status of the batteries just as you
would check the tank capacity of a diesel engine.
Changing over the plus (+) and minus (-) connections will
cause irreparable damage to the installation .
n
short-circuit the batteries by connecting the plus (+)
ever
pole to the minus (-) pole .
Connecting the main current cables
• Switch all electrical equipment off.
• Prevent any short circuits caused by tools, for example.
• Connect the positive (+) cable first, then the negative.
8 m (26 ft)
10 m (33 ft)
6 km/u (3.3 kn)
6 km/u (3.3 kn)
0.8 kW
1 kW
10.2 km/u (5.5 kn)
11.4 km/u (6.1 kn)
3.9 kW
6.7 kW
12.8 km/u (6.9 kn)
14.3 km/u (7.7 kn)
7.7 kW
13.4 kW
ENGLISH
W
arninG
W
arninG
12 m (39 ft)
6 km/u (3.3 kn)
1.1 kW
12.5 km/u (6.7 kn)
9.6 kW
15.7 km/u (8.4 kn)
18.9 kW
370301.01
25

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Eline075Eline100

Inhoudsopgave