• Remove the efficiency plate at the level of the top connection.
• From the inside of the appliance, remove the cover plate from the drain opening at the back of the
appliance.
• Loosen the connection piece at the top of the appliance and place it on the connection opening at the
back of the appliance. Ensure a good gas-tight seal.
• At the same time, place the efficiency plate at the rear connection with the opening facing upwards.
• When doing so, slide the efficiency plate down into the most open position; later, if necessary, adjust
the draught in the appliance by adjusting the plate. The latter is also applicable with a top connection.
• Now place the cover plate taken from the rear connection onto the duct opening on top of the
appliance. Ensure a good gas-tight seal.
• Carefully replace the retaining plate in the reverse order, making sure that all vermiculite panels of the
interior are placed tension-free.
• Place the additional sealing cover supplied on top into the recess of the casing.