INSTALLATION
General
A registered installer should only connect this appliance. The gas connection and the
electrical connection must comply with national and local regulations.
Read the separate safety instructions first!
Note!
•
This appliance must be earthed at all times.
•
Installation, maintenance or repairs should only be carried out by professionals who are
authorised by the manufacturer, as failure to do so will void the guarantee.
•
The device should be disconnected from the mains prior to installation, maintenance or
repairs. The device is only disconnected from the electric power if:
▷
the main switch of the domestic electrical system is switched off;
the fuse of the domestic electrical system has been completely removed;
▷
the plug has been pulled out of the socket.
▷
•
Faulty parts may only be replaced with original Etna parts. Only these parts are guaranteed
by Etna to meet the safety requirements.
•
If the connecting cable is damaged, it may only be replaced by the manufacturer, the
manufacturer's service organisation or equivalently qualified persons, in order to avoid
dangerous situations.
Electrical connection
230 V~ / 50/60Hz
The electrical connection must comply with national and local regulations. For the
Netherlands this includes the NEN 1010 amongst other standards.
•
The wall plug socket and plug should always be accessible.
•
Make sure that the cable does not come into contact with parts of the oven that may
become hot.
•
If you want to make a fixed connection, make sure that an omnipolar switch with a contact
separation of at least 3 mm is fitted in the supply cable.
•
The appliance should not be connected to the mains via a multiplug adapter or extension
cable, as the safe use of the equipment cannot be guaranteed.