Download Print deze pagina

Hammond SK PRO Handleiding pagina 183

Advertenties

Category
Parameter
Octave
External Zones
Transpose
Bank Select MSB
"n" staat voor;
Bank Select LSB
8: Ex Zone 1
Program Change
Allocate
9: Ex Zone 2
Key Range Low
A: Ex Zone 3
Key Range High
Volume
Expression Enable
P. Bend Enable
Mod. Enable
Damper Enable
Pan
Velocity Curve
Expression Minimum
Expression Maximum
Expression CC
NRPN
SysEx Address
MSB
LSB
MSB to LSB
(63)
(62)
1n
02
00
1n
1n
03
00
1n
1n
04
00
1n
1n
05
00
1n
1n
06
00
1n
1n
07
00
1n
1n
08
00
1n
1n
09
00
1n
1n
0A
00
1n
1n
0B
00
1n
1n
0C
00
1n
1n
0D
00
1n
1n
0E
00
1n
1n
0F
00
1n
1n
10
00
1n
1n
11
00
1n
1n
12
00
1n
1n
13
00
1n
SysEx
Data length 01 uses MSB only, length 02 uses MSB and LSB.
Length
3F 7E - 40 00 - 40 02 (-2 - ±0 - +2)
02
02
3F 7A - 40 00 - 40 06 (-6 - ±0 - +6)
03
02
00 - 7F (0 - 127)
04
01
00 - 7F (0 - 127)
05
01
00 - 7F (0 - 127)
06
01
00 - 03 (Off, Upper, Lower, Pedal)
07
01
00 - 7F: note number
08
01
00 - 7F: note number
09
01
00 - 7F (0 - 127)
0A
01
00, 01 (Off, On)
0B
01
00, 01 (Off, On)
0C
01
00, 01 (Off, On)
0D
01
00, 01 (Off, On)
0E
01
00 - 40 - 7F (Left - Center - Right)
0F
01
00 - 04 (Off, Hard - Easy)
10
01
00 - 3F (0 - 63)
11
01
40 - 7F (64 - 127)
12
01
00, 01, 02 (Off, 7, 11)
13
01
183