Deleting intermediate position II (tilt position)

Move the blind to intermediate position II.
First press and hold the STOP button and, within the next 3 seconds, press
and hold the UP button. Keep both buttons depressed until
▻ the receiver confirms.
► Intermediate position II is now deleted.
Intermediate position I
Intermediate position I is any shading solution position of
your choosing, situated between the upper and lower limit
positions. Both limit positions must be set before intermedi-
ate position I is set.
Intermediate position I is approached from the upper limit
position.
Programming intermediate position I
Move the blind from the upper limit position to the desired intermediate posi-
tion I.
First press and hold the STOP button and, within the next 3 seconds, press
and hold the DOWN button. Keep both buttons depressed until
▻ the receiver confirms.
► Intermediate position I is now saved.

Checking intermediate position I

Press the DOWN button twice within one second.
► The blind moves to intermediate position I.