Explanation of functions
Awning operation/Venetian blind operation
You can switch between awning operation and venetian blind operation.
Awning operation
By pressing a travel button, the awning moves to the set limit position in main-
tained operation mode.
Venetian blind operation (factory setting)
For venetian blind operation, you can operate the receiver in touch mode. If
you press the travel button for longer than 1 second, the venetian blind runs in
maintained operation mode.
Direction switch
The direction switch lets you change the direction of the tubular drive from
left-handed to right-handed rotation and vice versa. The factory default setting
has the switch turned as far to the right as possible.
Programming the transmitter
1.
Connect the radio receiver to the power supply.
2.
Now switch on the power.
3.
The radio receiver remains ready for programming for 3 minutes.
Programming the master transmitter
The master transmitter refers to the very first transmitter
programmed in a receiver. In contrast to subsequently pro-
grammed transmitters, the master transmitter enables,
among other things, the setting of limit positions (for drives
with integrated radio receiver) and the programming or de-
leting of further transmitters. Any transmitter that has separ-
ate UP, STOP, DOWN buttons and a programming button can
be a master transmitter.
If a transmitter is already programmed in the receiver, press
the programming button of the transmitter for 10 seconds.
Press the programming button of the transmitter for 3 seconds whilst in pro-
gramming mode.
► The receiver confirms.
Programming is now complete.
25 - en