2.3.6.7 Float Voltage
The float voltage can be set at 12-16/ 24-32/ 48-64V. Battery, the T-sense and V-sense
must be disconnected during setting.
Set the DS 3-7
Set the float voltage
Determine the required float voltage
DS-8
Vq.
DS-7 on
Determine the setting number.
DS-6
off
DS-5
off
DS-4
off
DS-3
off
24)/0,1
DS-2
Determine the LED indication.
DS-1
Press the pushbuttons until the
required LED indication is
displayed.
Increment size is 0.05 V.
2.3.6.8 Repeated Absorption
After each charging cycle, the charger will be switched back to the high charging current
after a pre-set time, following the float phase. This switch back action is called "repeated
absorption mode", see Appendix C.
Repeated Absorption Time (default: 1 hour)
The repeated absorption time can be set at 1 – 72 quarters of an hour.
Set the DS 3-7
Set the repeated absorption time
Determine the required Repeated
DS-8
absorption time Tq in quarters of an
DS-7 on
hour.
DS-6 on
Determine the setting number.
DS-5 on
DS-4
off
DS-3
off
DS-2
Determine the LED indication.
DS-1
Press the pushbuttons until the
required LED indication is
displayed.
Increment size is a quarter of an hour.
Scale = 0.1V
Minimum = 12/24V
Setting number = (Vq-
Scale = 1 quarter of an hour
Offset = 0
Setting number = Tq
Example
Required: float voltage is 28.5V.
Setting number= (28.5-24)/0.1 =
45.
LED indication =
0
0
0
1
2
2
2
2
4
5
Example
Required: Repeated absorption
time is 1 hour.
Setting number = 1 hour = 4
quarters of an hour
LED indication =
0
0
0
0
0
2
0
2
0
4
15