2.3.6 Setting the Charger (Multi/ MultiPlus)

When setting the charger, all connections between the battery and the Phoenix Multi must
be disconnected.
Please read our book "electricity on board"
(downloadable from our website www. victronenergy.com) for details and suggestions
about charging batteries.
2.3.6.1 Charger On/ Off (default:on)
The Phoenix Multi charger can be switched off if required.
The default is on.
Set the DS 3-7
Switch the charger on or off
Determine whether the charger is to
DS-8
be switched on or off.
DS-7 on
The default is On.
DS-6
off
The left-hand LED column is for On.
DS-5
off
The right-hand LED column is for
DS-4 on
Off.
DS-3
off
Press the pushbuttons until the
DS-2
required LED indication is
DS-1
displayed.

2.3.6.2 Preprogrammed Charging Characteristics

The Phoenix Multi/ MultiPlus has 3 pre-programmed charging characteristics:
Fixed Charging Characteristic:
The absorption period is a fixed preset period. Following the absorption mode, the charger
switches to float. In order to "refresh" the battery, the charger periodically switches back to
absorption.
Adaptive Charging Characteristic:
The absorption period depends on the charge delivered during bulk. This is followed by float
phase lasting 24 hours, after which the voltage is reduced by an additional 0.8 V, 1.6 V and
3.2 V resp. for 12 V, 24 V and 48V batteries. (reduced float). As with the Fixed-charging
characteristic, the charger will periodically switch back to absorption.
Adaptive Charging Characteristic with BatterySafe mode (default setting):
If, in order to quickly charge a battery, a high charge current in combination with a high
absorption voltage has been chosen, the Phoenix charger will prevent damage due to
excessive gassing by automatically limiting the rate of voltage increase once the gassing
voltage has been reached