PLAN AN ESCAPE ROUTE:
•
Make a map and mark all locations of doors and windows and a possible escape route. Note that you
may need an escape ladder on high floors.
•
Ensure everyone in the house knows the sound the smoke alarms produce and regularly practice use of
the escape route.
•
Leave the house immediately according to the plan when hearing the alarm. Every second counts:
so respond quickly. If you do not notice smoke or heat, check if everyone in the house is in a secure
location.
•
Do not open any doors without feeling whether the door is warm or if there is smoke coming from un-
derneath the doors. If it is, do not open that door. If the door is cold, put your shoulder firmly against the
door and open it a small amount to check for any heat or smoke first.
•
If there is much smoke, keep low and take shallow breaths, preferably through a moist towel. Call the
fire department as soon as you are safe outside.
BATTERY REPLACEMENT
The battery has a lifespan of 10 years. After 10 years you should replace the entire product because the
battery cannot be replaced.
SENSOR REPLACEMENT:
The sensor has a lifespan of 10 years. After 10 years you should replace the entire product because the
sensor cannot be replaced.
If the yellow LED illuminates within these 10 years, please refer to the paragraphs Reason for sensor fault
and Sensor fault caused by chemical gases.
SPECIFICATIONS:
Power supply:
Sensitivity and time:
standby consumption:
consumption at alarm:
Sound pressure at alarm:
Environmental conditions:
Storage conditions:
Dimensions:
Weight: 185g
Type:
Smoke sensor:
CO sensor:
Conforms to:
DEACTIVATE
Before disposing of the product at an appropriate collection point, deactivate the product. A plastic
deactivation key is located under the top of the product label. Break it off and insert it into the hole at
"Warning".
3VDC
(EVE CR17450L; PAIRDEER CR17450
30ppm CO, alarm is not activated within 120 minutes
50ppm CO, alarm is activated within 60~90 minutes
100ppm CO, alarm is activated within 10~40 minutes
300ppm CO, alarm is activated within 3 minutes
0.09~0.15 dB/m smoke, alarm is activated immediately
<20µA
<20mA
>85dB (3m distance)
0ºC ~ +40°C, 30~93% humidity
-20ºC ~ +50ºC, 10~95% humidity
135*40mm
Type B (unchecked output)
Photo-electric
Electro-chemical
EN14604:2005 + AC:2008
EN50291-1:2018
34