INSTALLATION:
1.
Install the mounting plate on a suitable spot
2.
Use the included plugs and screws.
3.
Now install the detector onto the mounting place.
The LED will briefly illuminate, the detector will emit a short audio signal.
4.
You can perform the first test by briefly pressing the test button, see also paragraph "Testing".
5.
6.
The detector is now functional.
USE:
Every 40 seconds , the green "POWER" LED will flash to indicate the detector is working.
1.
2.
The table below shows when the detector will sound the alarm.
CO concentration
33PPM
55PPM
110PPM
330PPM
In accordance to the EN 50291-1:2018 standard.
3.
When the alarm sounds, it will turn off within 40 seconds after moving the detector to a space with a
CO concentration below 40PPM and without smoke.
4.
The alarm sound can temporarily be turned off by pressing the TEST/SILENCE button (only during
smoke detection).
5.
Every 40 seconds, the detector will automatically perform an error check.
TEST/SILENCING:
When the detector is working under normal conditions, the sensor and siren should be tested at least every
week. Press the "TEST/SILENCE" button. The device will shortly beep once, then beep three times while
the red LED blinks, then beep four times shortly while the red LED blinks. This indicates the device is OK.
RESET ALARM:
The alarm can sometimes activate because of environmental influences, for example due to water vapor or
dust. You can press the "TEST/SILENCE" button to silence the alarm for 10 minutes.
It is not possible to stop the alarm if CO is detected.
The red LED continues flashing but the siren will stop for 10 minutes.
If there is still smoke detected after 10 minutes, the alarm will continue.
NO ALARM
until after
120 min.
60 min.
10 min.
-
32
ALARM
within
-
90 min.
40 min.
3 min.