MR07, MRR07, MH07
5.3
Heating cabinet MH07
The heating cabinet MH07 is suitable for use with a voltage of
fore be used in emergency vehicles.
The heating cabinet can warm up goods to a fixed temperature of 37 °C and keep
them warm.
5.4
Control elements MR07/MRR07/MH07
No. in fig. 2,
page 2
1
6
Installing and connecting the device
6.1
Removing the cooling unit (MR07 only)
➤ Bend back the guard plate (fig. 3 1, page 2) slightly.
➤ Remove the two fastening screws (fig. 3 3, page 2) using a long Phillips screw-
driver.
➤ Remove the cable binder from the rolled up cable.
➤ Unroll the cable.
➤ With the help of another person, lift up the cooling unit and turn it in the opposite
coiling direction of the suction line (fig. 3 2, page 2), until the suction line is
unrolled.
6.2
Installing the device
➤ Observe the following installation instructions for the place of installation:
– Avoid placing the device next to heat sources such as heaters, gas ovens, hot
water pipes, etc.
– Install the device in a dry, sheltered place.
– The device must be installed so that heated air from it can dissipate easily.
Therefore make sure there is adequate ventilation (fig. 4, page 3).
EN
Explanation
Temperature indication
Installing and connecting the device
12 Vg
and can there-
11