Stuurkaart, analoge ingangen:
Aantal analoge spanningsingangen .................................................................................................................. 1 st.
Klemnummer ...................................................................................................................................................... 53
Spanningsniveau ............................................................................................................. 0 - 10 V DC (schaalbaar)
Ingangsweerstand, R
.................................................................................................................. ongeveer 10 k
i
Max. spanning ................................................................................................................................................ 20 V
Aantal analoge stroomingangen ....................................................................................................................... 1 st.
Klemnummer ...................................................................................................................................................... 60
Stroomniveau .................................................................................................................. 0/4 - 20 mA (schaalbaar)
Ingangsweerstand, R
................................................................................................................... ongeveer 300
i
Max. stroom ................................................................................................................................................ 30 mA
Resolutie voor analoge ingangen ................................................................................................................... 10 bit
Nauwkeurigheid van analoge ingangen .............................................................. Max. fout 1% van volledige schaal
Scan-interval .............................................................................................................................................. 13,3 ms
De analoge ingangen zijn galvanisch geïsoleerd van de netspanning (PELV) en andere
hoogspanningsklemmen. Zie Galvanische scheiding.
Stuurkaart, pulsingangen:
Aantal programmeerbare pulsingangen ................................................................................................................. 1
Klemnummer ...................................................................................................................................................... 33
Max. frequentie op klem 33 .................................................................................................... 67,6 kHz (Push-pull)
Max. frequentie op klem 33 .................................................................................................. 5 kHz (open collector)
Min. frequentie op klem 33 ............................................................................................................................. 4 Hz
Spanningsniveau ............................................................................................... 0 - 24 V DC (PNP positieve logica)
Spanningsniveau, logische '0' .................................................................................................................. < 5 V DC
Spanningsniveau, logische '1' ................................................................................................................. >10 V DC
Maximumspanning op ingang ................................................................................................................... 28 V DC
Ingangsweerstand, R
.................................................................................................................... ongeveer 2 k
i
Scan-interval .............................................................................................................................................. 13,3 ms
Resolutie ........................................................................................................................................................ 10 bit
Nauwkeurigheid (100 Hz- 1 kHz) klem 33 ..................................................... Max. fout: 0,5% van volledige schaal
Nauwkeurigheid (1 kHz - 67,6 kHz) klem 33 .................................................. Max. fout: 0.1%van volledige schaal
De pulsingang (klem 33) is galvanisch geïsoleerd van de netvoeding (PELV) en andere
hoogspanningsklemmen. Zie Galvanische scheiding.
Stuurkaart, digitale/frequentie-uitgang:
Aantal programmeerbare digitale/pulsuitgangen ............................................................................................. 1 st.
Klemnummer ...................................................................................................................................................... 46
Spanningsniveau bij digitale/frequentie-uitgang .................................................................. 0 - 24 V DC (O.C PNP)
Max. uitgangsstroom bij digitale/frequentie-uitgang ................................................................................... 25 mA.
Max. belasting bij digitale/frequentie-uitgang ................................................................................................ 1 kΩ
Max. capaciteit bij frequentie-uitgang ........................................................................................................... 10 nF
Minimumuitgangsfrequentie bij frequentie-uitgang ........................................................................................ 16 Hz
Maximumuitgangsfrequentie bij frequentie-uitgang ...................................................................................... 10 kHz
Nauwkeurigheid op frequentie-uitgang ........................................................ Max. fout: 0,2 % van volledige schaal
Resolutie op frequentie-uitgang ..................................................................................................................... 10 bit
De digitale uitgang is galvanisch geïsoleerd van de netvoeding (PELV) en andere hoogspan-
ningsklemmen. Zie Galvanische scheiding.