3
Mount the tap aerator.
Cleaning the basket filter
1
Detach the cover plate. → See figure
sequence
1
, page 322.
2
Close both shut-off units or angle stop
valves. → See figure sequence
page 325.
3
Release the flush to relieve the pressure.
4
Remove both filter seats.
5
Remove and clean both basket filters.
6
Insert both basket filters.
7
Mount both filter seats.
8
Open both shut-off units or angle stop
valves.
9
Hold your hand under the washbasin tap to
test the function.
10
Mount the cover plate. → See figure
sequence
6
, page 329.
81064795304430731 © 02-2022
970.664.00.0(01)
Replacing the batteries
When using Geberit washbasin taps with battery
operation, the batteries will last for around 200,000
actuations. When the battery is almost dead, the
red LED will flash during flush actuation. → See
"Rectifying malfunctions", page 19
Prerequisite
– Two replacement batteries (alkaline battery,
1.5 V, AA) are available.
– There are no objects in the washbasin.
1
Detach the cover plate. → See figure
sequence
2
Remove the power supply cable from its
bracket and remove the battery
compartment. → See figure sequence
page 327.
3
,
3
Open the battery compartment and remove
the dead batteries.
4
Insert new batteries.
5
Close the battery compartment.
✓ The washbasin tap switches on. After
6
Insert the battery compartment and snap the
power supply cable into the bracket.
7
Hold your hand under the washbasin tap to
test the function.
8
Mount the cover plate. → See figure
sequence
1
, page 322.
approx. 5 seconds water flows.
6
, page 329.
EN
4
,
21