4. If required, change the data as described in the section Configuring Vehicle Data [} 103].
The headlight setting data shall correspond to the manufacturer's specifications.
5. Open the Headlight selection window with
6. Perform the headlight test as described in the section Performing headlight test [} 136].

8.6. Measured value calibration

Check the inclination calibration here. For this you can switch on or off the level sensor of the SEG V.

8.6.1. Switching On the Level Sensor

The level of the vertical and horizontal axis adjusts automatically in a way that any irregularity in the SEG V set-up area is
compensated if the level sensor is switched on.
Proceed as follows to switch on the level sensor:
1. Select >Measured value calibration< in the main menu.
The window Measured value calibration appears.
2. Open the list under Level compensation with
3. Select >on<.
The SEG V is balanced from a measuring technology standpoint.
Perform the horizontal/vertical calibration with
Abort the procedure with
ð The selection will be saved automatically.

8.6.2. Switching Off the Level Sensor

Surface irregularities of the SEG V set-up area will not be compensated if the level sensor is switched off.
Proceed as follows to switch off the level sensor:
1. Select >Measured value calibration< in the main menu.
The window Measured value calibration appears.
2. Open the list under Level compensation with
3. Select >Off<.
Perform the horizontal/vertical calibration with
Abort the procedure with
ð The selection will be saved automatically.
SEG V
.
.
.
.
.
.
.
Working with the Device | 8.
135