InStaLLatIOn
Safety
InStaLLatIOn
6.
safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1
general safety instructions
We can only guarantee trouble-free function and operational reli-
ability if original spare parts intended for the appliance are used.
6.2
regulations, standards and instructions
Note
Observe all applicable national and regional regulations
and instructions.
7.
appliance description
7.1
standard delivery
Delivered with the appliance:
- Dummy flange
- additional type plate
7.2
accessories
7.2.1 required accessories
Depending on the static pressure, safety assemblies and pressure
reducing valves are available. These type-tested safety assemblies
protect the appliance against unacceptable excess pressure.
7.2.2 Further accessories
In addition, heat exchangers, flanged and threaded immersion
heaters and thermal insulation are available as accessories.
If it is not possible to insert a rod anode from above, install a
segmented anode.
8.
Preparations
8.1
installation site
f Always install the appliance in a room free from the risk of
f
frost and near the draw-off point.
f Ensure the floor has sufficient load bearing capacity and
f
evenness (see chapter "Specification / Data table").
f Observe the room height and height when tilted (see chapter
f
"Specification / Data table").
8.2
transport
Use the lifting eyes at the top of the appliance to assist handling.
16
| SBP 1000-1500 E | E SOL | E cool
9.
Preparing for installation
9.1
Fitting the thermal insulation, if appropriate
f Position the appliance in its intended site.
f
f Fit the thermal insulation according to the instructions sup-
f
plied. For this, ensure that there is enough space for the
installation task. You can then link the appliance into the
heating system.
14
13
1 Cover
2 Top thermal insulation section
3 Top thermal insulation section
4 Top thermal insulation ring
5 Convection brake
6 R.h. thermal insulation section
7 Cover strip
8 Connection cover (including insulation)
9 Thermal insulation, flange
10 Flange cover
11 Thermal insulation section, bottom
12 Thermal insulation ring, bottom
13 Rose
14 Left thermal insulation section
1
2
3
4
5
6
7
8
9
10
11
12
www.stiebel-eltron.com