en
Fault
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
Appliance self-test
Your appliance features an automatic
self-test program which shows you
sources of faults which may be repaired
by customer service only.
Starting the appliance self-test
1. Switch off the appliance and wait 5
minutes.
2. Switch on appliance and hold down
the super button, Fig. "/2, for 3–5
seconds within the first 10 seconds
until an acoustic signal sounds.
The self-test programme starts.
While the self-test is running, a long
acoustic signal sounds.
When the self-test ends and an acoustic
signal sounds twice, your appliance is
in working order.
38
Possible cause
The evaporator (refrigeration
generator) in the NoFrost
system is covered in thick ice
and can no
longer be defrosted fully
automatically.
Remedial action
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance. Fig. *
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.
If the super button flashes for
10 seconds and 5 acoustic signals
sound, there is a fault. Inform customer
service.
Ending the appliance self-test
When the programme has ended, the
appliance switches over to normal
operation.