m
Warning
While changing over the door hinges,
ensure that the appliance is not
connected to the power supply. Pull out
the mains plug beforehand. To prevent
damaging the back of the appliance,
place adequate padding underneath.
Carefully place the appliance on its
back.
Note
If the appliance is placed on its back,
ensure that the wall spacer is not fitted.
Ambient temperature
and ventilation
Ambient temperature
The appliance is designed for a specific
climate class. Depending on the climate
class, the appliance can be operated at
the following temperatures.
The climate class can be found on
the rating plate. Fig. +
Climate class
Permitted ambient
temperature
SN
+10 °C to 32 °C
N
+16 °C to 32 °C
+16 °C to 38 °C
ST
+16 °C to 43 °C
T
Note
The appliance is fully functional within
the room temperature limits of the
indicated climatic class. If an appliance
of climatic class SN is operated at colder
room temperatures, the appliance
will not be damaged up to a temperature
of +5 °C.
Ventilation
Fig. $
The air on the rear panel of the
appliance heats up. Conduction of the
heated air must not be obstructed.
Otherwise, the refrigerating unit must
work harder. This increases power
consumption. Therefore: Never cover
or block the ventilation openings!
Connecting the
appliance
After installing the appliance, wait at least
1 hour until the appliance is switched on.
During transportation the oil in
the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for
the first time, clean the interior of
the appliance (see chapter "Cleaning
the appliance").
Electrical connection
The socket must be near the appliance
and also freely accessible following
installation of the appliance.
m
Warning
Risk of electric shock!
If the length of the mains cable is
inadequate, never use multiple sockets
or extension leads. Instead, please
contact Customer Service for
alternatives.
The appliance complies with protection
class I. Connect the appliance to
220–240 V/50 Hz alternating current via
a correctly installed socket with
protective conductor. The socket must
be protected by a 10 A to 16 A fuse.
en