12. CLEANING
Remove dirt with a soft cloth damped in oil free soap water & rinsed with clean water. Disinfec-
tion can be carried out with an alcohol-based solution (with damped wipes).
If other cleaning solutions are used, check that they are not abrasive and they are compatible
with: Cu,Fe,Al alloy, brass, plastic materials of the components, labels and gas.
Do not use cleaning solutions containing ammonia!
EN
Do not immerse in water or any liquid.
Do not clean electrical connections when the power is on. Make sure the connections are dry
before turning power back on.
13. DISPOSAL
13.1. LIFE TIME
The maximum life time of the product is 10 years at compliance of Examination shedule (chapter
10). At the end of the product's life time, the MM90 must be withdrawn from service. To prevent
reuse, the owner shall make the MM90 impossible to use, or contact GCE (or GCE authorised
customer or third party) for return of the product.
13.2. MANUFACTURING DATE
The manufacturing date is included in MM90 serial number which is marked on back plate.
Serial number composition is the following: YYMMXXXXX
Y: 2 last numbers of the year of manufacture
M: month of manufacture
X: production number
The perforation in the device label indicates the year when the equipment has to be disposed
off .
13.3. REPAIR
Repair activities of GCE product must be carried out by GCE or authorized repair centers.
Contact GCE for further information about service available in your area.
All labels on the equipment must be kept in good, legible condition by the owner and the user
during the entire product life time.
Use only genuine GCE components.
13.4. DISPOSAL AT THE END OF THE PRODUCT'S LIFE TIME
Product must be recycled in compliance with the national and local regulations.
No part contains any chemical materials burdensome environment.
The owner of the device shall prevent the reuse of the product and handle the product in com-
pliance with "Directive of European Parliament and Council 2008/98/EC on waste".
In accordance to Article 33 of REACH GCE, s.r.o. as responsible manufacturer shall inform all
customers if materials containing 0.1% or more of substances included in the list of Substance
of Very High Concern (SVHC).
The most commonly used brass alloys used for valve bodies and other brass components
contain 2-3% of lead (Pb), EC no. 231-100-4, CAS no. 7439-92-1. The lead will not be released
to the gas or surrounding environment during normal use. After end of life the product shall be
scrapped by an authorized metal recycler to ensure effi cient material handling with minimal
impact to environment and health.
To date we have no information that indicates that other materials containing SVHC of concen-
trations exceeding 0.1% are included in any GCE product.
12/84