6
Safety Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 The hot and cold supplies must be of equal
pressures.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms.
• Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous
flow heaters if the flow pressure is at least 0,15 MPa.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
anti-pollution function
4
English
Symbol description
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
150 ±16 mm
cold right - hot left
Assembly see page 32
To adjust the hot water limiter on single lever
mixers, please see page 35. No adjustment
is necessary when using a continuous flow
water heater.
Maintenance (see page 33)
The non return valves must be checked
regularly according to DIN EN 1717
in accordance with national or regional
regulations (at least once a year).
Do not use silicone containing acetic acid!
Dimensions (see page 31)
Flow diagram
(see page 31)
Spare parts (see page 36)
Operation (see page34)
Cleaning (see enclosed brochure)