Download Print deze pagina

Würth WIG 180 AC/DC Vertaling Van De Originele Gebruiksaanwijzing pagina 25

Advertenties

Gas post-flow
20 – 500 %
time correction
Ancillary parameters
The values set at the factory have been optimised
by an automatic system.
These factory settings can be used unchanged for
most welding operations.
Further possibilities for fine tuning are explained in
the following tables.
Parameter
Range
5 - 200% of
Hotstart IS
1)
main current
Hot start time
0 - 20
tS
Seconds
1)
Dynamic
0 - 200%
Arc
1)
The welding current is automatically increased
1)
with decreasing welding voltage. The dynamic
electric arc indicates the ratio between main current
and automatic increase.
Parameter
Range
5 - 200% of
Starting current
2)
main current
Starting current-
0 - 20
time
Seconds
2)
Pulse scanning ra-
tio
(only in Pulse
1 - 99%
2)
operating mode)
Indicates the percentage ratio between main
2)
current I1 and secondary current I2. With a setting
of 30, the ratio is 30% l1 to 70% I2.
Parameter
Range
5 - 200% of
Final current
1)
main current
Final current
0 - 20
time tS
Seconds
1)
AC-Balance
10 - 90%
3)
AC-Balance
30 - 200 Hz
3)
Positive pole
current correc-
10 - 200%
tion
3)
[37]
100
Factory
Code
setting
125
1.0
100
Factory
Code
setting
50
0.1
50
Factory
Code
setting
25
0.2
35
60
100
For optimum weld formation, the arc is drawn with
plus (+) pole current during AC TIG welding. This
plus pole current is pre-set in the machine and can
be increased or decreased by the percentage
shown.
Parameter
Range
Ignition peak
10 - 200%
correction
2)
After striking, a peak striking current is set to sta-
bilise the electric arc. This ignition peak current is
pre-set in the machine and can be increased or
decreased by the percentage shown.
Parameter
Range
HF On/Off
On - Off
2)
Version info
-
Only with Electrode welding
1)
Only with TIG welding
2)
Only with AC welding
3)
The ancillary parameters are set separately:
Briefly press the buttons Welding method [24]
and Operating mode [41] simultaneously. The
code of the ancillary parameter and its value ap-
pear alternately on the 7-segment display [32].
Press the button Main parameters [42] until the
desired parameter is displayed.
Set the desired value with the rotary knob [35].
Press the button Welding method [24] or Oper-
ating mode [41] briefly to quit this mode.
The changed values are saved.
3
Note
All the welding parameters can also be
changed during the welding process for
more effective setting.
Factory
Code
setting
100
Factory
Code
setting
On
-
25

Advertenties

loading

Deze handleiding is ook geschikt voor:

5952 000 181