Art.
Serial number
Year of manufacture
The year of manufacture of the device can be determined from the serial number, which you will find on the type
plate. The 11th and 12th digit of the serial number reduced by 10 indicates the year of manufacture. (Example:
Serial number xxxxxxxxxx31xxxx results in year of manufacture 2021 (31-10 = 21))
IP code
Class of insulation
Cooling type
Labelling
Dimension (LxWxH) in mm
Weight
Mains ratings
Mains voltage
Frequency
Positive mains tolerance
Negative mains tolerance
Power cord
Mains plug
Current consumption I
1 at no-load
Mains fuse slow-blow
(TIG / Electrode)
Power factor at I
2 max
Power factor I
2 max
Max. permissible mains impedance Z
61000-3-11/-12
Recommended generator power
Rated input voltage U
1
Max. rated input current I
Max. effective input current I
No-load voltage U
0
Welding electrode
Welding range min - max
No-load voltage
(peak value to EN 60974-1)
Current setting
Curve characteristic
Current consumption I
1 max
Maximum effective mains current I
Weldable electrodes
20
Technical Data
according to IEC
max
2)
1max
2)
1eff
2)
2)
1eff
5952 000 181
951511675031020011
2021
IP 23 S
F
F
CE, S
493 x 191 x 390
17.7 kg
230 V AC
50-60 Hz
15%
15%
3 x 2.5 mm²
Schuko socket
0.26 A
16 A
0.61 λ
0.97 cos ϕ
23 mΩ
> 6.0 kVA
230 V
27 A
16 A
84 - 99 V
10 - 150 A
20.4 - 26.0 V
<113 V/DC
stepless
falling
27.0 A
16.0 A
1.5 - 4.0 mm